PRECAUTIONS

Note in Turning ON

When using PSB-915IA, do not need to care following note.

Regarding the turning on,  -9V must be supplied later.

When turning off, -9V must be off first or in the same time with other powers.

Otherwise -9V is remained, the IC might be broken.

Note in handling CCD

Static charge prevention

CCD image sensors are easily damaged by static discharge. Before handling, be sure to take the following

protective measures.

• Use an earth band in handling by hands.

• Install a conductive mat on the floor or working table to prevent the generation of static electricity.

• For the shipment of mounted substrates, use boxes treated for the prevention static charges.

Dust and dirt protection

• Operate in clean environments.

• Do not either touch glass plates by hand or have any object come in contact with glass surface. Should dirt

stick to a glass surface blow it off with an air blow.

• Clean with cotton bud and ethyl alcohol if the glass surface is grease stained.  Be careful not to scratch the

glass.

• Remove a protective tape on the CCD to be applied for electrostatic protection, before the use.  Do not reuse

the tape.

Do not expose to strong light (sun rays) for long periods.

Exposure to high temperatures or humidity will affect the characteristics.

Accordingly avoid storage or usage in such conditions.

CCD image sensor is precise optical equipment that should not be subject to mechanical shocks.

Summary of Contents for CCB-M Series

Page 1: ...Instruction Manual COMPACT MONOCHROME CARD CAMERA CCB M series CCB M25 M25CE CCB M35A M35ACE CCB M27B M27BCE CCB M37 M37CE Ver 2 0 English ...

Page 2: ...CCB M series Table of Contents GENERAL 1 SPECIFICATIONS 4 BLOCK DIAGRAM 8 PRECAUTIONS 9 EXTENTIONAL FUNCTIONS 13 OPTIONAL ACCESSORIES 14 Attach Circuit example for VS Gen lock ...

Page 3: ...ne board comes with CCD image sensor and the Aluminum plate for the lens mounting named CCD board another board comes with the processing components named Process board By connecting 16P connector CN202 to additional circuit or modification electronic shutter speed adjustment AGC ON OFF selection external synchronization working and so on are possible Standard Connection Connectors of CN203 Video ...

Page 4: ...1 3 510 H 492 V EIA 500 H 582 V CCIR 768 H 494 V EIA 752 H 582 V CCIR 380 TVL 570 TVL 0 3 lx F1 2 0 2 lx F1 2 0 25 lx F1 2 0 3 lx F1 2 6 48 4 82 6 35 4 83 4 9 3 69 4 9 3 67 6 45 4 84 6 47 4 83 4 88 3 66 4 89 3 64 2 1 Interlaced Internal 1 60 to 1 10000sec EIA 1 50 to 1 10000sec CCIR more than 48 dB AGC OFF 1 0 Vp p 75 Ω Composite 5 0 1Vdc less than 100mA 15 0 3Vdc less than 15mA 9 0 4Vdc less than...

Page 5: ...3 CCB M series SPECIFICATIONS Dimensions unit mm CCB M25 CE CCB M27B CE CCB M35A CE CCB M37 CE Note Make space over the screw B2 of CCD board as the screw projects from the Aluminum plate by max 0 6mm ...

Page 6: ...CB M35A CE CCB M37 CE unit mm 1 20 10 11 7 55 0 2 15 1 0 3 9 0 0 2 18 0 0 4 3 4 0 3 1 41 0 15 Glass thickness 0 75mm Center of effective sensing area 1 5 7 0 15 11 4 0 2 6 1 0 15 12 2 0 2 3 35 0 4 1 41 0 15 Center of effective sensing area 9 5 10 3 8 16 9 Glass thickness 0 75mm ...

Page 7: ...18P Connect CCD board and Process board CN202 16P for Extentional functions refer to 5 1 CN203 2P Video Out Pin No Descriptions Mating Plug 1 Video Out 75Ω 1 0Vp p JST 02ZR 8M 2 GND CN204 4P Power Supply In Pin No Descriptions Mating Plug 1 15 0 3 VDC JST 04ZR 8M 2 9 0 4 VDC 3 5 0 1 VDC 4 GND ...

Page 8: ...umidity of 90 to 95 for 96 4h and then subjected to standard atmospheric conditions for 1h After this procedure measurements shall be mode Refer to IEC Pub 68 2 3 for other procedures The specimen shall be subjected to 5 continuous cycles each as shown in the table below Following the final cycle the specimen shall be stored at standard atmospheric condition for 1h after which measurements shall b...

Page 9: ...7 CCB M series BLOCK DIAGRAM CCD CN201 Sample Hold Timing Generator Signal Generator AGC Iris 75 Ω Driver 15V 9V 5V CN203 Video Out CN204 DC Power In CN202 Function Control CN101 γ ...

Page 10: ...ent of mounted substrates use boxes treated for the prevention static charges Dust and dirt protection Operate in clean environments Do not either touch glass plates by hand or have any object come in contact with glass surface Should dirt stick to a glass surface blow it off with an air blow Clean with cotton bud and ethyl alcohol if the glass surface is grease stained Be careful not to scratch t...

Page 11: ...2holes on an Aluminum plate of CCD board Ref No 1 2 Connect CCD board and Process board with a connector then fix Process board to 1 b ø2 8 2holes with M2 screws Refer to the dimensions Fix the shadow part on Process board Ref No 2 The screw head which is fixing the Aluminum plate and Process board rises on the Aluminum plate by Max 0 6mm The housing chassis have to be made in covering the head CC...

Page 12: ...1 D2 TEST 2 EXT HR VR HD VD ID GND CLK IN Iris Out DC 1 3V Det Out DC 2 0V AGC Control Voltage In Shutter Speed Data Set Preset H Internal Sync L External Sync H Preset L Horizontal Reset In Vertical Reset In External Sync Mode Field Pulse Out Internal Sync Mode HD Out VD Out Line Discrimination 28MHz clock out Internal Sync Mode Typ 700 500 See the graph 1 1 1 1 1 1 2 2 2 Max 800 1500 Unit mVp p ...

Page 13: ...h terminals are high On the PSB 915IA short lands for settling the electronic shutter by connecting the lands The terminal connect to ground 3 16 17 R406 16P IC401 CXA1310AQ CN202 Gain Cont IC401 AGC Cont 5V R451 15KΩ R406 0Ω R452 27KΩ 40 AGC control characteristics 30 20 10 0 0 1 2 3 4 5 AGC CONT V CN202 40 AGC MAX control characteristics RV403 30 20 10 0 0 1 2 3 4 5 AGC MAX V 3 14 IC401 GAIN dB ...

Page 14: ...pply internal clock 4 Supply 28MHz clock synchronizing HD of 12P on CN202 and with external sync source to CN202 16P CLK IN 5 Supply VD signal inputting from External sync source to CN202 11P VR Ref Circuit example for VS Gen Lock Gamma CCB M25 M25CE CCB M35A M35ACE C403 which is on 7P at IC401 on Process board is to be re mounted into C451 This case it is necessary to re adjust AGC Remove C403 on...

Page 15: ...BCE and CCB M37 M37CE from field accumulation mode to frame accumulation mode It needs the following modification Please note that this modification is effective only for CCB M27B M27BCE and CCB M37 M37CE Mount the resister 10K on R304 of Process Board VB 001 at B side B side Process Board VB 101 R304 ...

Page 16: ...r the optional Auto Iris Lenses NOTE It needs to adjust PSB 915IA when using CCL lenses as follows Adjust RV201 on PSB 915IA to change 1pin of CN205 Iris Out to 800mVp p object gray scale chart 1 Connect CN205 16P and CN202 on Camera s Process board with board to board connector 2 Connect CN102 4P and CN204 on Camera s Process board 3 Supply DC5V to CN206 4 When using the Auto Iris Lens optional a...

Page 17: ...es prepared according to the focal length CCE 50M CCE 150R Extension Cable These are flexible cables to remote CCD board from Process board with connecting CN101 and CN201 Length CCE 50M 50mm CCE 150R 150mm Focal Length H View Angle 1 2 CCD CCL M03XE CCL M05XE CCL M07XE These products are available with limited quantity Auto Iris Lens CCL M03XE CCL M05XE CCL M07XE f 3 6 mm f 5 0 mm f 7 5 mm 91 1 6...

Page 18: ... notice Technical information contained herein is for reference only and does not convey any license by any implication or otherwise under any intellectual property right or other right of sony or third parties Sony cannot assume responsibility for any right infringements arising out of the use of this information ...

Page 19: ...klands Weybridge Surrey KT13 0XW Tel 44 990 331122 Fax 44 1932 817011 Nordic Per Albin Hanssons vag 20 S 214 32 Malmo Sweden Tel 46 40 190 800 Fax 46 40 190 450 Italy Via Galileo Galilei 40 I 20092 Cinisello Balsamo Milano Tel 39 2 618 38 431 Fax 39 2 618 38 402 Sales Office Japan Image Sensing Products Sales Department Broadcasting Professional Systems Company Sony Corporation 4 16 1 Okata Atsugi...