1-4. Unleaded Solder
Boards requiring use of unleaded solder are printed with a
lead free mark (LF) indicating the solder contains no lead.
(Caution: Some printed circuit boards may not come
printed with the lead free mark due to their particular size.)
: LEAD FREE MARK
m
.
Be sure to use the unleaded solder for the printed circuit
board printed with the lead free mark.
.
The unleaded solder melts at a temperature about 40
d
C
higher than the ordinary solder, therefore, it is recom-
mended to use the soldering iron having a temperature
regulator.
.
The ordinary soldering iron can be used but the iron tip
has to be applied to the solder joint for a slightly longer
time. The printed pattern (copper foil) may peel away if
the heated tip is applied for too long, so be careful.
1-5. Service Know-How
1-5-1. When the Optical Unit ASSY is
Replaced
1.
Write the 3DGamma/LookUpTable/DDC/LCK/
OGMTable/CSMatrixTable data contained in the
attached CD-R.
See “1-6-3. Writing 3DGamma/LookUpTable/DDC/
LCK/OGMTable/CSMatrixTable Data” for more
about how to write data.
2.
Change the IRIS data to the values of the IRIS adjust-
ment data stored in the supplied CD-R. For how to
change the data, refer to “1-5-3. IRIS Copy”.
3.
Change the Panel Driver Gain B data to the values of
the adjustment data stored in the supplied CD-R.
For how to change the data, refer to “1-5-4. Panel
Driver Gain B Copy”.
1-5-2. When the Board is Replaced
1.
When the QA board is replaced
Remove IC602 from the old QA board and install
IC602 by reusing the removed IC602. If reuse of IC602
is not possible, follow the procedure described below.
a)
Change the IRIS data to the values of the IRIS
adjustment data before replacement. (For the
method to change the IRIS data, refer to “1-5-3.
IRIS Copy”.)
In case if the data cannot be changed, perform the
IRIS adjustment.
(For the IRIS adjustment, refer to “2-4. IRIS
Adjustment.”
b) Obtain the former OGMTable data from the
original QA board before replacement as follows.
(For the method of obtaining the former OGM
Table data from the original QA board before
replacement, refer to “1-6-4. How to Obtain the
3DGamma/LookUpTable/DDC/LCK/OGMTable/
CSMatrixTable Data from the Board”.)
Write down the obtained OGMTable data as
follows.
(For the method of writing down the obtained
OGMTable data, refer to “1-6-3. Writing 3DGam-
ma/LookUpTable/DDC/LCK/OGMTable/CSMa-
trixTable Data”.)
In case if the former OGMTable data cannot be
obtained from the original QA board before
replacement, perform the W/B adjustment. (For
the W/B adjustment, refer to “2-3. White Balance
Adjustment on Servicing”.)
c)
Return the Panel Driver/Gain B value back to its
original value before the QA board is replaced.
(For the method of returning the above value to
the original value, refer to “1-5-4. Panel Driver
Gain B Copy”.)
In case if the original data cannot be copied,
perform the Panel Driver Gain B Adjustment.
(For the method of Panel Driver Gain B Adjust-
ment, refer to “2-5. Panel Driver Gain B Adjust-
ment”.)
2.
When the CB, GA, GB, HA, HB, NF, NR, QB, TA,
TL, J, U, or V board is replaced
No particular adjustments are needed.
3.
When the CA board is replaced
Remove IC2501 and IC4002 from the old CA board
and install them to the new CA board that is supplied
as the repair part, before replacement.
Summary of Contents for BRAVIA VPL-VW70
Page 1: ...VIDEO PROJECTOR VPL VW70 REMOTE COMMANDER RM PJVW70 SERVICE MANUAL 1st Edition ...
Page 30: ......
Page 38: ......
Page 90: ......
Page 100: ......
Page 116: ......
Page 136: ......
Page 146: ......
Page 158: ......
Page 160: ...English Sony EMCS Corporation 2008JR16 1 Ichinomiya Tec 2008 VPL VW70 UC E 9 883 668 01 ...