11
KDL-26FA400/26N4000/32FA400/32N4000/37FA400/37N4000
KDL-26FA400/26N4000/32FA400/32N4000/37FA400/37N4000
Viewing the Diagnostic List
1. TV must be in standby mode. (Power off).
2. Press the following buttons on the Remote Commander within a second of each other:
DISPLAY
Channel
5
Volume
+
TV POWER .
The Self Check list displays.
This is the SAME as accessing Service Adjustments.
Results for all of the following diagnostic items are displayed at the bottom of the screen. No error has occurred if the screen displays a “0”.
QR0.5-C510
Model Information:32N4000 8000010
ADC Auto Calibration
Power On Time: 00001H
SMPTE
ColorBar100
ITU 709
Gain
424
1020
420
1020
456
16
8
1840
128
1592
128
1608
424
1020
422
1020
460
16
Offset
Cr
Y
Cb
ITU 601
VGA
2:MAIN POWER 0 6:BL 0
3:DC ALERT1 0 7:TEMP 1
4:DC ALERT2 0 8:Audio 0
5:DC ALERT3 0
Gain
Offset
Gain
Offset
Factory Default
Indicates an error was detected
Indicates no error was detected
Model Information & Serial Number
Software Version
Power Time
Resets all settings
to the Factory Defaults
Diagnostic
List
Stored Data
from ADC calibration
(from factory)
Clearing the Diagnostic List
CAUTION
: To remove the error indicator number you have to reset the settings back to the Factory Defaults.
This action over-writes all customer
settings.
Before performing this reset, contact the customer to determine what adjustments they have made.
1. Using the remote commander, select
Factory Default
button.
2. To reset the Diagnostic List, select
Yes
.
3. To start Auto Program, select
Yes
.
NOTE: Allow 30+ minutes for Auto Program to complete.
4. Using the customers information, reset their adjustments.