![Sony BKNW-116 Installation Manual Download Page 8](http://html.mh-extra.com/html/sony/bknw-116/bknw-116_installation-manual_398815008.webp)
1-2 (E)
BKNW-116
n
AC power supply is required a capacity which is commen-
surate with rush current.
If the capacity of the AC power supply is not enough, the
breaker of AC power of a supply side may operate or this
unit may not operate normally.
1-4-2. Power Cord
w
Use the specified power cord only when connecting.
Never use a injured power cord.
Power cord for the customer in the U.S.A. and Canada.
1
Power cord (approx. 2.5 m)
!
1-557-377-11
2
Plug holder (brown)
3-613-640-01
Contact your local Sony Sales Office/Service Center.
Power cord for the customer in Europe.
1
Power cord (approx. 2.5 m)
!
1-782-929-11
2
Plug holder (brown)
3-613-640-01
Contact your local Sony Sales Office/Service Center.
If the unit is used in the area except above, contact your
local Sony Sales Office/Service Center.
1
2
AC inlet
1-3. Operating Conditions
1-4. Power Supply
AC inlet
1
2
1-3. Operating Conditions
Operating temperature: 5
d
C to 40
d
C
(When the inner of the unit becomes less than 5
d
C, the
hard disk portion does not start up because of entering
into warm up mode. The inner of the unit becomes 5
d
C
or more, the hard disk portions start up automatically.)
Operating humidity:
25% to 80%
(Condensation not allowed)
Storage temperature:
_
20
d
C to 60
d
C
Locations to avoid:
.
Areas where the unit will be exposed to direct sunlight
or any other strong lights.
.
Areas near heat sources.
.
Dusty areas or areas subject to vibration.
.
Areas with strong magnetic field.
.
Areas with much electrical noise.
.
Areas with much static electricity.
.
Areas that is impossible to find a specified room for
installation.
(Refer to “1-5. Installation Space”)
.
Areas windtight
Horizontal condition: Do not slant the front and rear of the
unit more than 30
d
.
c
Fix the unit securely to avoid slipping if the unit is not
operated at horizontal place.
1-4. Power Supply
1-4-1. Voltage and Power Requirements
n
Be sure to operate the unit within the range of following
power voltage.
Power voltage:
AC 100 to 240 V
±
10%
Power frequency:
50 Hz or 60 Hz
Power consumption: 285 W (AC100 V IN: 3 A)
(AC240 V IN: 1.5A)
Rush current:
Power voltage 100 V IN: 7 A
Power voltage 240 V IN: 7 A
This unit’s power line has a switching regulator with the
power factor 98 %.