Page 1: ...DISK UNIT BKNW 116 INSTALLATION MANUAL 1st Edition Serial No 10001 and Higher SY Serial No 30001 and Higher J ...

Page 2: ...g WARNING This manual is intended for qualified service personnel only To reduce the risk of electric shock fire or injury do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so Refer all servicing to qualified service personnel WARNUNG Die Anleitung ist nur für qualifiziertes Fachpersonal bestimmt Alle Wartungsarbeiten dürfen nur von...

Page 3: ...1 2 Supplied Accessories and Packing Materials 1 1 E 1 3 Operating Conditions 1 2 E 1 4 Power Supply 1 2 E 1 4 1 Voltage and Power Requirements 1 2 E 1 4 2 Power Cord 1 2 E 1 5 Installation Space 1 3 E 1 6 Rack Mounting 1 4 E 1 7 How to Connect Hybrid Recorder 1 8 E 1 7 1 Connection 1 8 E 1 7 2 Setting of Hybrid Recorder 1 8 E 2 Service Overview 2 1 Signal Inputs and Outputs 2 1 E 2 2 Filter Clean...

Page 4: ... to hybrid recorder and so on Section 2 Service Overview Explains signal input output and filter cleaning Related manuals Besides this installation manual the following manuals are available for this hard disk unit BKNW 116 Operation manual Supplied with BKNW 116 This manual is necessary for application and operation of the BKNW 116 Maintenance manual available on request This manual describes the...

Page 5: ...he four specified feet which is attached to the bottom of the unit on the floor If there are no feet on the bottom attach them before putting this unit or put this unit gently so that no sound is generated Never operate the unit for 30 seconds after the power is turned off The disks in HDD rotate by inertia for a while after the power is turned off In this case the heads are in the unstable state ...

Page 6: ......

Page 7: ... Q ty Disk array cable 1 769 670 31 1 Operation manual _ 1 Individual carton 3 200 082 01 1 Cushion 3 200 083 01 2 Installation manual _ 1 Protection sheet standard 3 704 355 01 1 n Power cord is not supplied in this unit For the power cord refer to Section 1 4 2 1 1 Installation Procedure n This unit has built in hard disk drives HDDs Pay careful attention when installing the unit Be careful not ...

Page 8: ... does not start up because of entering into warm up mode The inner of the unit becomes 5dC or more the hard disk portions start up automatically Operating humidity 25 to 80 Condensation not allowed Storage temperature _20 dC to 60 dC Locations to avoid Areas where the unit will be exposed to direct sunlight or any other strong lights Areas near heat sources Dusty areas or areas subject to vibratio...

Page 9: ...onsideration of the ventilation and service operation The air flows of this unit are shown below Do not block the exhaust part and ventilation of front and side panels so that the air flows enough Moreover when this unit is installed without rack mount ing it is recommended that the clearance at the upper left and right sides is at least 4 cm n If the ventilation is not enough the unit may be dama...

Page 10: ...Adjust so that the temperature inside of the rack is in the range of the unit s operating temperature Connect the hybrid recorder after mounting this unit in the rack Specified Rack Mount Kit RMM 130 Option Parts packed in RMM 130 Slide rails 2 Rack angles handles 2 Rail brackets 4 Plate nuts large 4 Plate nuts small 4 Screws PSW4 x 16 4 Screws B4 x 8 8 Hexagon socket head cap screws 8 Flat washer...

Page 11: ... Remove the ten screws shown in the figure from both sides left and right of the unit 4 Attach the two inner rails to both sides left and right of the unit with eight screws of ten removed in the step 3 Tightening torque 120 x 10 2 N m 12 2 kgf cm 3 Attachment of rack angles handles 1 Remove the four screws shown in the figure from both sides left and right of the unit n Keep these screws B4 x 6 t...

Page 12: ... other outer rail temporarily in the same way 2 Stagger the ball retainer as shown in the figure And attach the rail bracket to the outer rail temporarily with plate nut large and two screws Attach the rail bracket to the other outer rail temporarily in the same way 5 Attachment of outer rails 1 As shown in the figure attach the outer rail temporari ly to the center portion of 4U for installing th...

Page 13: ...ls on both sides left and right toward you 2 Pull the rails out as the equal length from both sides left and right 3 Lift the unit by hands and insert the inner rails into the intermediate rails slowly n The mass is 26 5 kg when putting this unit rack angles handles and inner rails together 4 While pressing the stoppers on the both sides left and tight push the unit into the rack slowly 5 Take the...

Page 14: ... Preparations Disk array cable 1 769 670 31 Supplied with this unit SCSI terminal connector 1 774 818 11 Supplied with hybrid recorder Use the specified cable and connector If not the operation may become unstable Procedures n Turn off the power before connecting 1 Disconnect the SCSI terminal connector from SCSI connector of the hybrid recorder 2 As shown in the figure connect this unit to the hy...

Page 15: ...B2 43 SCSI DB2 _ 10 SCSI DB3 44 SCSI DB3 _ 11 SCSI DB4 45 SCSI DB4 _ 12 SCSI DB5 46 SCSI DB5 _ 13 SCSI DB6 47 SCSI DB6 _ 14 SCSI DB7 48 SCSI DB7 _ 15 SCSI DBP 49 SCSI DBP _ 16 SCSI DIFFSENS 50 SCSI GND 17 SCSI TERMPWR 51 SCSI TERMPWR 18 SCSI TERMPWR 52 SCSI TERMPWR 19 SCSI RESERVED 53 SCSI RESERVED 20 SCSI ATN 54 SCSI ATN _ 21 SCSI GND 55 SCSI GND 22 SCSI BSY 56 SCSI BSY _ 23 SCSI ACK 57 SCSI ACK ...

Page 16: ...it n Wait more than 30 seconds after turning off the power then clean Procedures 1 Unscrew the two screws then remove the front panel n The front chassis may heat up When removing the front panel take care not to touch the front chassis 2 Remove the filter from the front panel 3 Remove the dust on the filter using a vacuum cleaner n Be sure to remove the filter from the front panel before cleaning...

Page 17: ...des acquéreurs de l équipement décrit dans ce manuel Sony Corporation interdit formellement la copie de quelque partie que ce soit de ce manuel ou son emploi pour tout autre but que des opérations ou entretiens de l équipement à moins d une permission écrite de Sony Corporation Das in dieser Anleitung enthaltene Material besteht aus Informationen die Eigentum der Sony Corporation sind und ausschli...

Page 18: ...Printed in Japan Sony Corporation 1999 1 08 Broadcasting Professional Systems Company 1998 BKNW 116 J SY J E 3 862 492 01 2 ...