3-3
3-3. BHD Board Adjustment
(HD SDI Adjustment)
This section describes the adjustments of the Y LEVEL, PB
LEVEL, and PR LEVEL when the HD SDI signal is input to
BHD board.
Equipment Used
Oscilloscope
Connection
Setting the Monitor
Set the INPUT CONFIGURATION menu of the SET UP
menu as follows.
FORMAT ................ HD SDI
SLOT NO ............... 2
INPUT NO .............. 1
Adjusting Procedure
1. Y LEVEL Adjustment
Adjustment
Standard
Adjusting Point
• Input the 100% color bar signal
TP201 (YOUT) output level:
The adjustment menu is located in
(100% White Ref. 100% Saturation)
660
±
10mVp-p
the BHD BOARD menu of the
into the HD SDI input terminal.
MAINTENANCE menu.
• Connect an oscilloscope to TP201
Y LEVEL
(Y OUT)
2. PB LEVEL Adjustment
Adjustment
Standard
Adjusting Point
• Input the 100% color bar signal
TP202 (PB OUT) output level:
The adjustment menu is located in
(100% White Ref. 100% Saturation)
660
±
10mVp-p
the BHD BOARD menu of the
into the HD SDI input terminal.
MAINTENANCE menu.
• Connect an oscilloscope to TP202
PB LEVEL
(PB OUT)
3. PR LEVEL Adjustment
Adjustment
Standard
Adjusting Point
• Input the 100% color bar signal
TP203 (PR OUT) output level:
The adjustment menu is located in
(100% White Ref. 100% Saturation)
660
±
10mVp-p
the BHD BOARD menu of the
into the HD SDI input terminal.
MAINTENANCE menu.
• Connect an oscilloscope to TP203
PR LEVEL
(PR OUT)
660
±
10mVp-p
660
±
10mVp-p
660
±
10mVp-p
1
2
3
4
5
TP201
TP202
TP203
6
7
A
B
C
D
E
F
G
CN1
Oscilloscope