LOG SENSE
6.Command Specification
SONY AIT-3Ex drive SDX-800V series Ver.1.0
6-19
6.6.6. Tape Alert Log Page
Bit
Byte
7 6 5 4 3 2 1 0
0
Reserved
Page Code (2Eh)
1
Reserved
2
(MSB)
Page Length (140h)
3
(LSB)
5n-1
(MSB)
Parameter Code (n)
5n
5n+1
DU (0)
DS (1)
TSD (0)
ETC (0)
TMC (00)
LBIN (0)
LP (0)
5n+2
Parameter Length (1)
5n+3
Value of Flag
The value of
n
in the Parameter Code field shall be in the range of 1 to 64.
A value of one in the Value of Flag field indicates the flag is set.
Each flag will be cleared to zero in the following conditions:
• At power on cycle
• When Tape Alert Log page is read
• When specified corrective action has been performed
• SCSI bus reset or Bus Device Reset message
• Log Select reset
There are three types of flags, listed below in order of increasing severity:
Table 6-20: Tape Alert flag types
Severity
Urgent User
Intervention
Risk of Data Loss
Explanations
C (Critical)
X
X
W (Warning)
X
X
I (Information)
X