LOG SENSE
7. ATAPI Packet Command Specification
SONY AIT-2 Turbo drive SDX-570V series Ver.1.0
7-19
Executing Mechanism Commands
Forward-ATF-On 01h
Spool-Forward 07h
Thread 0Fh
Un-tension 10h
Reverse 11h
Spool-Reverse 17h
Unthread 20h
Stop 21h
Eject 22h
Still 23h
Forward 30h
Load 31h
Re-tension 32h
Re-start 33h
Pinch-On 36h
Pinch-Off 37h
Diagnostics 80h
7.6.9.
Read and Write Frame Error Counter Page Codes 34h, 35h
The Read Write Error Counter Page has the following format. All fields in these logs are initialized to ZERO in the
following circumstances:
At Power ON
After a cassette loading
After a user sends a request for initialization through Log Select
After a reset
Following configuration for error rate testing
Table 7-26: LOG PAGE Frame Error Counters (34h, 35h)
Bit
Byte
7 6 5 4 3 2 1 0
0
Reserved
Page Code (34h or 35h)
1
Reserved
2
(MSB)
3
Page Length (38h/48h)
(LSB)
4
(MSB)
5
Parameter Code
(LSB)
6
0 (DU)
1 (DS)
0 (TSD)
0 (ETC)
00 (TMC)
Reserved
0 (LP)
7
Parameter Length (n-3)
8
n
Parameter Value
Frame Error Counter Page (Read 35h)
Frame Error Counter Page (Write 34h)
Parameter Code: This identifies which parameter of data is being transferred. The following codes are supported
for each Error Counter Page.