11. TECHNICAL DATA
53
LZ T 123 7 605 P1C
Talk Mode:
The module is switched ON and a voice/data call is in
progress.
The power consumption during transmission in Talk Mode is measured at
maximum transmit power.
The power consumption in Standby Mode is measured at the maximum
paging rate (Paging Rate 2).
Current Consumption with ex4.8V Supply Active
For the following calculations it was assumed that the ex4.8V load
is 70mA.
These tables do not include the power consumption associated with any
drive current supplied via further Control Terminal outputs, e.g. OUT-1
or OUT-2.
Supply Voltage
5V
12V
32V
Power Down Mode:
Av Max
Av Max
Av Max
5
15
5
15
20
50 mA
Standby Mode (typical):
Frequency
Av Max
Av Max
Av Max
850/900 MHz
112
196
45
79
19
33 mA
1900/1800 MHz
112
206
45
81
19
32 mA
Talk Mode (typical):
Frequency
Av Max
Av Max
Av Max
850/900 MHz
306 1316
126
556
53
213 mA
1900/1800 MHz
256 1046
106
386
43
153 mA