background image

 

 

 

4

 

Commissioning

 and installing  

SONAPHONE T  

 

10

  

Commissioning and installing 

4.1 

Inserting the batteries 

 

Caution! 

Make sure you install the batteries in the correct position. The device may 
be damaged if they are not properly fitted. 

 

The correct position for installing the batteries is shown on the device. 

 Unscrew the battery compartment cover. 

 Insert the batteries into the battery compartment according to the 

illustration on the bottom of the device. 

 When the device is operational, the battery (1.5 V) status is shown on the 

display. 

Appropriate accumulators can also be used to operate the device. The 
charge status for the accumulators (1.2 V) is then shown approximately. 

 

4.2 

Connecting the power supply unit  

The power supply unit has no charging function. 

 Unscrew the protective cover for the power supply connection. 

 Connect the power supply unit. 

 The device recognises the connection of the power supply unit –  even 

when it is operating –  and automatically switches over to mains power 
operation. 

 

4.3 

Installing probes 

 

Caution! 

Make sure the probe connector is in the correct position. The device and 
the probe may be damaged during installation. 

 

The slot for probes is provided with a notch which indicates the correct 
position for insertion. 

 Install the required probe in the specified position. You must feel the 

connector click into place. 

 The probe is installed and ready to use. 

Summary of Contents for SONAPHONE T

Page 1: ...Ultrasonic Transmitter SONAPHONE T Version 2 0 Operating Manual...

Page 2: ...et www sonotec de 2013 SONOTEC Ultraschallsensorik Halle GmbH All rights reserved The content of this manual is the property of SONOTEC Ultraschallsensorik Halle GmbH and is protected by copyright Dup...

Page 3: ...sducer 8 3 6 SONOSPHERE spherical transmitter optional 8 4 Commissioning and installing 10 4 1 Inserting the batteries 10 4 2 Connecting the power supply unit 10 4 3 Installing probes 10 4 4 Uninstall...

Page 4: ...at any time It contains all the information needed to ensure proper and efficient use along with all the instructions to ensure safe operation of the SONAPHONE T 1 2 Symbols used Hazards or special in...

Page 5: ...power sources in the operating voltage range specified in the technical data Operation and storage of the SONAPHONE T outside the temperature ranges specified in the technical data is not permitted Th...

Page 6: ...range If you place the ultrasonic transmitter for leak detection in a closed system the ultrasonic signals escape via leaks in the system and can be identified there using an ultrasonic detector in th...

Page 7: ...ff 3 View of the current sound intensity 4 Battery status view 5 Function of the enter key in the menu Table 2 Description of the display elements Description of the operating buttons Figure 3 Operati...

Page 8: ...3 6 SONOSPHERE spherical transmitter optional The SONOSPHERE spherical transmitter is used to test large and contorted areas Depending on requirements it can be used as a semi sphere with 7 transmitt...

Page 9: ...3 Device description SONAPHONE T 9 Table 5 Elements of the spherical transmitter...

Page 10: ...he device The charge status for the accumulators 1 2 V is then shown approximately 4 2 Connecting the power supply unit The power supply unit has no charging function Unscrew the protective cover for...

Page 11: ...4 Commissioning and installing SONAPHONE T 11 4 4 Uninstalling probes Press the button to unlock the connector Pull the probe carefully and straight to remove it from the slot...

Page 12: ...0 in regular steps of 5 40 is the standard setting Press the arrow buttons to increase the sound intensity or to decrease it The current sound intensity is shown on the display 5 3 Switching on modula...

Page 13: ...is 50 Press the enter key once to go to the contrast menu option Press the arrow buttons to set the display contrast value between 0 and 100 Confirm the value with the enter key to go to the time menu...

Page 14: ...and aggressive cleaning agents by immersion in liquids 7 Maintenance and troubleshooting Caution When there are errors or problems it is not permitted to open the SONAPHONE T or accessories or to unde...

Page 15: ...0 C Protection type Device IP54 Probe IP20 Dimensions Without probe LWH 130 x 85 x 30 mm With L50 probe Length 170 mm Probe Length 52 mm 22 mm Items supplied Ultrasonic transmitter L50 transmitter Opt...

Reviews: