background image

SSP 2015

page 1

STATUTORY INFORMATION/ PRECAUTIONS

IMPORTANT SAFETY INSTRUCTIONS

1.   Read and follow these instructions.
2.  Do not use this apparatus near water.
3.  Clean with dry cloth only.
4.  Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
5.  Do not install near any heat sources such as radiators, stoves, or other apparatus (including amplifiers)  
 

that produce heat.

6.  Do not defeat the safety purpose of the polarized or grounding-type plug. A grounding type plug has two  
 

poles and a third grounding pole. The thick pole is provided for your safety. If the provided plug does not  

 

fit into your outlet, consult an electrician for replacement of the outlet 

7.  Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles,  
 

and the point where they exit from the apparatus.

8.  The apparatus shall be connected to a MAINS socket outlet with a protective earthing connection.
9.  Unplug this apparatus during lightning storms or when unused for long periods of time.
10.  Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been  
 

damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects  

 

have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate  

 

normally, or has been dropped.

The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert 
the user to the presence of “un-insulated dangerous voltage” within the product’s enclosure 
that may be of sufficient magnitude to constitute a risk of electric shock.

The exclamation point within an equilateral triangle is intended to alert the user to the 
presence of important operating and maintenance (servicing) instructions in the literature 
accompanying the product.

WARNING: 

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE

CONNECTORS
XLR-type connectors are wired as follows (IEC60268 standard): pin 1: ground, pin 2: hot (+), pin 3: cold (-).

Summary of Contents for SSP 2015

Page 1: ...SSP 2015 dual channel 15 band graphic equalizer I owners manual www sonodyne com ...

Page 2: ...ective earthing connection 9 Unplug this apparatus during lightning storms or when unused for long periods of time 10 Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture ...

Page 3: ...quency bands Switchable boost cut ranges of 6dB or 12dB 12dB per octave 50Hz low cut filter Front panel bypass switch 12dB input gain range 4 segment LED ladders for monitoring output levels XLR and TRS Inputs and Outputs Frequency Response of 10Hz 50kHz Dynamic range of greater than 112dB IN THE BOX Verify that the equalizer s package contains the following Equalizer unit AC power cord Operating ...

Page 4: ...ITCH AND LEDS This switch selects the two boost cut ranges of the equalizer either 6dB or 12dB 5 CLIP LED This LED lights whenever any internal signal level reaches 3dB below clipping 6 OUTPUT BAR GRAPH LEVEL These four LEDs indicate output level of the equalizer The red LED is 3dB below clipping and is marked as 18dBu It monitors the level at the output of the equalizer after all other processing...

Page 5: ... connectors for the inputs and outputs can be used for balanced or unbalanced connections The use of more than one connector at a time for the inputs could unbalance balanced lines cause phase cancellation short a conductor to ground or cause damage to other equipment connected to the equalizer More than one output may be used simultaneously as long as the combined parallel load is greater than 2k...

Page 6: ...lipping is 22dBu ref 0 775Vrms INSTALLATION CONSIDERATIONS HOOKUPS AND CABLING The Equaliser is designed for nominal 4dBu levels The equalizer can be used with either balanced or unbalanced sources and the outputs can be used with either balanced or unbalanced loads provided the proper cabling is used INPUT CABLE CONFIGURATIONS The equalizer has an input impedance of 40kΩ balanced and 20kΩ unbalan...

Page 7: ...is caused by a ground loop Systematically remove and or connect the audio grounds of the devices in the signal path Remember for safety you must maintain connection to chassis ground Never lift a safety ground IF YOU SUSPECT THE HUM IS NOT CAUSED BY A GROUND LOOP Check the audio at an earlier stage in the audio chain Low level equipment should be mounted away from power amplifiers to avoid inducti...

Page 8: ...anced unbalanced in 2 kΩ or greater 18dBm balanced unbalanced in 600Ω SYSTEM PERFORMANCE BANDWIDTH FREQUENCY RESPONSE DYNAMIC RANGE SIGNAL TO NOISE RATIO THD NOISE INTER CHANNEL CROSSTALK 20Hz 20kHz 0 5 1dB 10Hz 50kHz 0 5 3dB Typically 112dB Typically 90dB 0 004 80dB 20Hz 20kHz FUNCTION SWITCHES EQ BYPASS LOW CUT RANGE Bypasses the graphic equalizer section in the signal path Activates the 50 Hz 1...

Reviews: