Product description | 3
KD-536 | 1000051 | EN | 02
7 / 20
3 Product description
3.1 Technical data
sonnenProtect 2500
System data
Nominal power
2,500 W
Maximum power (30 sec.)
3,000 W
Output voltage
230 VAC +/- 10 %
Nominal frequency
50 Hz
Power factor range
0 capacitive ... 0 inductive
Max. input current
20 A
Max. output current
13 A
Short-circuit current
19.5 A
Network configuration in emergency operation
TN
Mains connection
single-phase, L / N / PE
Mains connection fuse
Miniature circuit breaker | Type B | 20 A
Operating concept
Single-phase power supply via emergency cir-
cuit(s). The switch to emergency operation takes
place automatically through the storage system.
Switchover time
max. 15 seconds
Threshold power
none (starting from 0 W)
Dimension/Weight
Dimension (H/W/D) in mm
230/200/122
Weight in kg
4.3
Safety / Protective devices
Protection class
I / PE conductor
Degree of Protection
IP30
Overvoltage category
III
Protective functions
Overcurrent protection, fault current protection
Residal current device (RCD)
integrated (Type A | 30 mA)
Ambient conditions
Environment
Indoor (conditional)
Pollution degree
2
Operating temperature range
-5 °C ... 45 °C
Max. rel. humidity
90%, non-condensing
Permissible installation altitude
2,000 m above sea level
Additional ambient conditions
The ambient conditions prescribed for the stor-
age system apply.
Table 2: Technical data