![Sonnen sonnenBatterie pro 2.0 Instructions For Use Manual Download Page 12](http://html1.mh-extra.com/html/sonnen/sonnenbatterie-pro-2-0/sonnenbatterie-pro-2-0_instructions-for-use-manual_1321594012.webp)
4 | Electrical installation
12 / 16
Instructions sonnenBatterie pro 2.0
4.4 Electrical connection
4.4.1 Connecting the mains line
Observe the following points:
• The mains connection must be protected with a type B miniature circuit breaker, rated
current 13 A or 16 A.
• The cable cross-section from the miniature circuit breaker to the electrical consumer
must be adapted to suit the larger loads if necessary.
Connect the mains line as described in the installation instructions for the eco 8.0 stor-
age system (section ‘Connecting the mains line’).
4.4.2 Connecting the Ethernet lines
The connection to the customer router is established via a switch. If the customer router
has a sufficient number of free slots, the three storage systems can be connected directly
to the router. A switch is not necessary in this case.
Connect the Ethernet lines as shown in figure System components [P. 8]. The Ethernet
cables, the switch and the router are not included in the scope of delivery.
The required output type can be found in section ‘Connecting the Ethernet cable’ in
the storage system installation instructions.
4.4.3 Connecting the Modbus line
Connect the Modbus cable as shown in figure System components [P. 8].
4.4.4 Connecting the signal line
Connect the signal cable to the master as described in the storage system installation
instructions.
Summary of Contents for sonnenBatterie pro 2.0