Safety
Intended use
Any use of the system other than the intended
use can cause serious injury, death, and damage to
the product or other assets.
• The storage system must only be used to store
electrical power.
• The storage system must only be used with the
battery modules provided.
• The storage system is intended for indoor use
only.
• The intended use includes knowledge and
application of the information in this manual as
well as all delivered product documentation.
Failure to comply with the warranty
conditions and the information listed in
this installation and operating manual
will void any warranty claims.
Prohibited uses
Only authorized electrically qualified persons can
perform work on electrical parts.
• Do not use the storage system in vehicles.
• Do not use the storage system in wet locations.
• Do not use the storage system in areas at risk
of explosion (flour dust, sawdust, etc.).
• Do not expose the storage system to direct
sunlight.
• Do not use the storage system in areas where
the ammonia content of the air exceeds 20
ppm.
• Do not use the storage system when corrosive
gases are present.
• Do not use the storage system higher than
9,842 feet (3,000 meters) above sea-level.
• Do not operate the storage system at
temperatures outside of the allowed ambient
temperature range of 41°F - 113°F (5°C - 45°C).
• Do not operate the storage system at a
humidity higher than 90%.
General safety instructions
• Do not modify the storage system.
• Do not use the storage system if it has been
damaged.
• Ensure that all safety systems are in perfect
working order.
• Read this manual with care.
General warnings
Despite all of the care that goes into the design
of the storage system, fires are still possible. A fire
can release substances contained in the battery
modules.
In the event of a fire in the storage system or its
surroundings:
• Only fire fighters wearing proper protective
clothing (including gloves, masks, and
breathing apparatus) may enter the room with
the burning storage system.
• A fire in the storage system can be
extinguished by conventional agents.
• The use of water is advisable to cool the battery
modules and thus prevent the thermal runaway
of modules that are still intact.
If contents escape:
• Do not enter the room.
• Avoid contact with the escaping electrolyte.
• Contact your fire department.
Pertinent information on battery modules
include:
• The battery modules have a rated voltage
of 51.2 VDC and are thus in the range of
protective extra-low voltage (below 60 VDC).
• The battery modules contain no metallic
lithium.
Summary of Contents for sonnenBatterie eco Gen 2
Page 2: ...This page intentionally left blank ...
Page 4: ...This page intentionally left blank ...
Page 6: ...This page intentionally left blank ...
Page 8: ...This page intentionally left blank ...
Page 13: ...5 Storage System Dimensions 14 17 74 11 25 59 54 3 8 25 5 8 ...