4 Switching on the storage system
The storage system can only be switched on if the public network voltage has
been switched on first.
4.1 Switching on the grid voltage
Switch on the grid voltage using the AC miniature circuit breaker.
4.2 Switching on the storage system
NOTICE
If the storage system can’t be switched on:
Do not attempt switching on the storage system more than three times.
Contact the service!
ð
Further attempts can damage the battery modules.
Fuse switch F1 establishes the connection between the battery and the inverter.
Illustration 7: Fuse switch F1 on the top side of
the storage system
Switch on fuse switch F1.
The storage system then starts up and performs a self-test. Once the self-test is success-
ful, the storage system is ready to operate.
When the storage system is in normal operation, the sonnen Eclipse pulses white (see
Function of the sonnen Eclipse [P. 16]).