5.3 Offline problems and solutions
There are different types of fault information tips for MP5 Plus Writer in offline mode.
SONiX provide solutions for different problems, as shown in table 5-2:
Item
Problems
Solutions
1
Err0
A: Take off MCU ,and repower;
B: Take off MCU, if this prompt is still exist, please contact the agent or SONiX;
2
Err1
Please make sure that the MCU is blank;
3
Err2
A: Please check the connection between MCU and MP5 Plus Writer;
B: Please confirm 20-pin cable not longer than 15cm;
C: Please confirm the socket is in normal status, clean and replace on a regular
basis;
D: The MCU may have open / short problems and so on;
If you still have questions, please contact agent or SONiX;
4
Err3
A: Please confirm the MCU is consistent with the source code ;
B: Please check the connection between MCU and MP5 Plus Writer;
C: Please confirm 20-pin cable not longer than 15cm;
D: Please confirm the socket is in normal status, clean and replace on a regular
basis;
E: The MCU may have open / short problems and so on;
If you still have questions, please contact agent or SONiX;
5
ErrF
Please confirm the source code is consistent with the INI file about Rolling Code;
6
Err5
Placed the other type MCU;
7
Err6
A: Please put the MCU and the corresponding transition board;
B
:
Placed the other type MCU or transition board, Please replace;
C
:
Placed the wrong location or direction;
D
:
The MCU may have Open/Short problems;
8
No response
Plug the USB again
,
download the .SN8/.Hex again
;
9
LEDs Flashed
Plug the USB again
,
download the .SN8/.Hex again
;