Page 1: ...RB DA6 6 Way Stereo Distribution Amplifier RB DA6G 6 Way Stereo Distribution Amplifier With Output Gain Control RB DA6P 6 Way Stereo Distribution Amplifier With Phoenix Connectors User Handbook ...

Page 2: ...ice and does not represent a commitment on the part of the vendor Sonifex Ltd shall not be liable for any loss or damage whatsoever arising from the use of information or any error contained in this manual No part of this manual may be reproduced or transmitted in any form or by any means electronic or mechanical including photocopying recording information storage and retrieval systems for any pu...

Page 3: ...Correct Mains Lead v Installation Information vi Atmosphere vi Electromagnetic Radiation vi Fitting Redboxes vi WEEE RoHS Directives Sonifex Statement vii RB DA6 RB DA6G RB DA6P 6 Way Stereo Distribution Amplifier 1 Connections and Operation 3 RB DA6 RB DA6G Inputs Left and Right 3 RB DA6 RB DA6G Stereo Outputs 1 6 Mono Outputs 1 12 3 RB DA6P Inputs Left and Right 3 RB DA6P Stereo Outputs 1 6 Mono...

Page 4: ...arge Redbox Rear Rack mount Kit vi Fig 1 1 RB DA6 Front Panel 1 Fig 1 2 RB DA6P Front Panel 1 Fig 1 3 RB DA6G Front Panel 1 Fig 1 4 RB DA6 RB DA6P Block Diagram 2 Fig 1 5 RB DA6G Block Diagram 2 Fig 1 6 RB DA6 RB DA6G Rear Panel 2 Fig 1 7 RB DA6P Rear Panel 3 Fig 1 8 RB DA6P Phoenix Connectors 3 Fig 1 9 RB DA6 RB DA6P Front Panel 4 Fig 1 10 RB DA6G Front Panel 4 ...

Page 5: ...d to the Company s premises at the Purchaser s expense iv any Goods or parts of Goods replaced shall become the property of the Company v no work whatsoever other than normal and proper maintenance has been carried out to the Goods or any part of the Goods without the Company s prior written consent vi the defect has not arisen from a design made furnished or specified by the Purchaser vii the Goo...

Page 6: ...ge of the Company and the Company accepts no liability in respect of its accuracy beyond that set out in Condition a f Subject to Condition e no representation condition warranty or other term express or implied by statute or otherwise is given by the Company that the Goods are of any particular quality or standard or will enable the Purchaser to attain any particular performance or result or will...

Page 7: ...shipped in protective packaging and should be inspected for damage before use Where an item is found to have transit damage notify the carrier immediately with all the relevant details of the shipment Packing materials should be kept for inspection and also for if the product needs to be returned Returning the Warranty Card In order to register the date of purchase so that we can keep you informed...

Page 8: ...hat the correct rating and type of fuse is used Incorrectly rated fuses could present a possible fire hazard under equipment fault conditions The fuse rating for the RB DA6 RB DA6G RB DA6P is 230 or 115 V operation 1A 5 x 20mm SB The active fuse is fitted on the outside rear panel of the unit Power Cable and Connection An IEC power connector is supplied with the RB DA6 RB DA6G RB DA6P which has a ...

Page 9: ... your required operating voltage and mains lead After the product code add UK for 230V UK 3 pin to IEC lead EC for 230V European Schuko 2 pin to IEC lead US for 115V 3 pin to IEC lead AU for 230V Australasian 3 pin to IEC lead Fig C Mains Lead Table E g order RB DA6P UK for a UK IEC lead to be supplied SAFETY INFORMATION S AF E T Y IN F ORMAT ION ...

Page 10: ...Redboxes can be fixed to the underside of a mixing desk or other surfaces using 4 2mm holes in the sides and fixed with 2 x M4 screws or 2 x No 6 countersink wood screws They can also be rack mounted with either the front or rear of the Redbox positioned at the front of the rack Rear Mounting The RB DA6 RB DA6G RB DA6P The RB RK3 1U rear panel rack kit can be used for large Redboxes such as the RB...

Page 11: ...in the European Union s Restriction of Hazardous Substances RoHS directive The RoHS directive limits the use of certain hazardous substances currently used in EEE manufacture including lead mercury cadmium hexavalent chromium and halide containing compounds PBB polybrominated biphenyl and PBDE polybrominated diphenyl ether Elimination of these substances will result in more environmentally friendl...

Page 12: ...ining to any product which has been manufactured by Sonifex Ltd using components which have been declared by the manufacturers as Lead Free All statements by Sonifex Ltd of RoHS compliance are based on component manufacturer documentation WEEE ROHS INFORMATION W EEE ROH S I N F OR MATI ON ...

Page 13: ...hat a short circuit on one won t affect the others The RB DA6P is a version of the RB DA6 audio distribution amplifier which uses Neutrik Phoenix stlye connectors instead of XLR inputs and outputs Each unit is shipped with the mating connectors so that wires can be simply terminated using a small flat blade screwdriver The inputs and outputs are electronically balanced and can be wired unbalanced ...

Page 14: ... 4 RB DA6 RB DA6P Block Diagram Fig 1 5 RB DA6G Block Diagram Left Outputs Balanced Left Input Balanced Stereo Mono Right Input Balanced Right Outputs Balanced Mono 7 12 Gain Gain 1 2 3 4 5 6 1 2 3 4 5 6 Left Outputs Balanced Left Input Balanced Stereo Mono Right Input Balanced Right Outputs Balanced Mono 7 12 1 2 3 4 5 6 1 2 3 4 5 6 ...

Page 15: ...ut is individually buffered so that a short circuit on one output will not affect the others They have the following connections Pin 1 Screen Pin 2 Phase Pin 3 Non phase Fig 1 7 RB DA6P Rear Panel RB DA6P Inputs Left and Right The Phoenix style input connectors can take balanced professional levels or unbalanced by using the front panel gain controls and by connecting the non phase to the signal g...

Page 16: ... Output Gain Control RB DA6G The output gain on the RB DA6G can be varied 8dB to 18dB by adjusting the pre set potentiometers These are accessible through the holes in the front panel The RB DA6G has output gain controls on every output Stereo Mono Operation The mode of operation may be switched between a stereo distributed channel to 6 stereo channels and a mono channel to 12 mono channels by the...

Page 17: ...can be unbalanced Outputs RB DA6 RB DA6G 12 x XLR 3 pin male Balanced can be unbalanced Inputs RB DA6P 2 x Phoenix 3 pin female Balanced can be unbalanced Outputs RB DA6P 12 x Phoenix 3 pin male Balanced can be unbalanced Mains Input Filtered IEC 110V 120V or 220 240V fused 6W maximum Fuse Rating Anti surge fuse 100mA 20 x 5mm 230VAC Anti surge fuse 250mA 20 x 5mm 115VAC Equipment Type RB DA6 6 wa...

Page 18: ...6 Redbox RB DA6 RB DA6G RB DA6P User Handbook NOTES N OT E S ...

Page 19: ...Redbox RB DA6 RB DA6G RB DA6P User Handbook 7 N OT E S NOTES ...

Page 20: ...w w w sonifex co uk t 44 0 1933 650 700 f 44 0 1933 650 726 sales sonifex co uk ...