Warranty and Safety Information
ii
Sonifex HY-03 User Handbook
Unpacking the HY-03
The HY-03 is shipped with the following equipment. Please check your packaging to ensure that you have all of the items
below. If anything is missing, please contact the supplier of your equipment immediately.
Item Quantity
HY-03 & HY-03S
Quantity
HY-03T
HY-03 automatic telephone hybrid
1
2
Telephone line lead (RJ11 to RJ11)
1
2
Telephone line lead (RJ11 to BT plug)
1
2
Handset socket adapter (BT socket to RJ11 plug)
1
2
Spare fuses (2) for 230V & 115V operation
1
2
IEC Mains lead fitted with moulded mains plug
1
2
Handbook and warranty card
1
1
Each HY-03 is shipped in protective packaging and should be inspected for damage before use. Where an item is found to
have transit damage, notify the carrier immediately with all the relevant details of the shipment. Packing materials should
be kept for inspection and also for if the product needs to be returned.
Returning the Warranty Card
In order to register the date of purchase so that we can keep you informed of any design improvements or modifications,
it is important to complete the warranty registration document that is enclosed and return it to Sonifex Ltd in the UK.
For your own records you should write down the serial number (which can be found on the rear of the HY-03).
Serial Number
………………………………..
Safety of Mains Operated Equipment
This equipment has been designed to meet the safety regulations currently advised in the country of purchase
and it conforms to the safety regulations specified by use of the CE Mark.
Warning :
There are no user serviceable parts inside the equipment. If you should ever need to look inside the unit,
always disconnect the mains supply before removing the equipment covers.
Warning:
The HY-03 line socket should only be connected with apparatus complying with BS6301, and the connection to
the network must not be hard wired. Interconnection directly or indirectly with equipment ports marked in accordance with
BS6301 to unmarked ports may produce hazardous conditions on the network and advice should be obtained from a
competent engineer before such a connection is made.
Warning:
This apparatus
must
be earthed by means of the earth connector on the rear panel, and the connection to the
telecommunications network should be removed
before
disconnecting the earth. Disconnection of this earth connection
may render the equipment unsafe, with a consequential possible electrical shock hazard from exposed metallic parts.
Warning:
The barriered ports ‘LINE’ and ‘HANDSET’ must not be connected directly or indirectly to the unbarriered ports,
‘MIC/LINE INPUT’, ‘OUTPUT’ or ‘REMOTES’.
Voltage Setting Checks
The mains input voltage selector switch on the rear panel of the equipment sets the operating voltage of the HY-03 to be
either 115V or 230V. Ensure that the machine operating voltage is correct for your mains power supply. The safety
specification of your HY-03 complies with local requirements and must be earthed through the mains connector.
Fuse Rating
The HY-03
is supplied with a single fuse in the live conducting path of the mains power input. For reasons of safety it is
important that the correct rating and type of fuse is used. Incorrectly rated fuses could present a possible fire hazard,
under equipment fault conditions. The fuse ratings for HY-03
are:
115 V operation - 200mA
5 x 20mm SB
230 V operation - 100mA
5 x 20mm SB
The active fuse is fitted on the outside rear panel of the unit. If you change the voltage of the HY-03, make sure to change
the fuse also.