Technical Specification
16
Sonifex HY-02 User Handbook
Power 1 & Power 2
The hybrid units are connected to the central power supply by a 7 way IP 40 connector with the following assignments :
Pin 1 : +15V
Pin 2 : -15V
Pin 3 : Common
Pin 4 : Earth
Pin 5 : Earth
Pin 6 : Remote line connect switch
Pin 7 : Remote line connect lamp
Mains Power
The central power supply is connected via an IEC Connector (CEE22, 230V - 50Hz, or 115V – 60Hz).
Protective Earth Terminal
This earth bond screw terminal is a screen terminal which must be connected to an earth point.
RD-02R Connection Details
The HANDSET and NTTP PORT connections are as per the HY-02. The other connections are :
Divert Control
The divert control is a 5 way IP40 connector which should be connected to the REMOTE socket on the rear of the power
supply unit.
Ring Lamp
This is a 3 way IP40 socket (678 series) which is assigned as follows :
Pin 1 : Not connected
Pin 2 : Remote ring light NPN emitter
Pin 3 : Remote ring light NPN collector