•
Select
the
radio
button
for
the
Wireless
Guide
wizard.
•
Click
Next
and
follow
the
prompts
in
the
Wireless
Guide
wizard.
For
more
information
and
complete
procedures,
refer
to
the
latest
SonicOS
Administration
Guide
.
For
international
(non
USA
or
Japan)
SOHO
Wireless
appliances,
you
are
asked
to
select
a
country
code
when
using
the
Wireless
Guide
or
when
you
initially
navigate
to
the
Wireless
>
Settings
page.
Be
sure
to
select
the
country
code
for
the
country
in
which
the
appliance
will
be
deployed,
even
if
you
are
not
currently
in
that
country.
IMPORTANT:
If
you
select
the
country
code
for
Canada,
it
cannot
be
changed
except
by
contacting
SonicWall
Support.
6
Register
product
Point
your
browser
to
the
appliance
LAN
IP
address
(default:
https://192.168.168.168
),
and
log
in
using
the
administrator
credentials.
•
Click
Register
on
the
System
>
Status
page
under
the
Security
Services
section.
•
Log
in
using
your
MySonicWall
account
name
and
password.
If
you
do
not
have
a
MySonicWall
account,
TIP:
Registering
the
appliance
from
SonicOS
requires
that
DNS
Server
settings
are
configured
on
the
WAN
(X1)
interface.
click
the
Create
MySonicWall
account
link
to
create
an
account.
•
MySonicWall
directly
obtains
the
necessary
information
from
the
appliance.
When
finished,
you
will
see
a
message
that
registration
has
been
completed.
Click
Continue
.
NOTE:
Your
appliance
must
be
registered
to
download
the
latest
firmware.
7
Get
the
latest
firmware
•
In
a
Web
browser,
navigate
to
http://www.mysonicwall.com
•
Click
Downloads
and
select
SOHO
W
Firmware
from
the
Software
Type
drop
‐
down
menu.
•
Click
the
link
for
the
firmware
you
want
and
save
the
file
to
a
location
on
your
computer.
•
On
the
SOHO
W
appliance,
navigate
to
the
System
>
Settings
page.
Click
the
Upload
New
Firmware
button.
•
Click
the
Browse
button
to
select
the
firmware
you
just
downloaded,
then
click
Upload
.
•
Click
the
Boot
icon
for
your
new
firmware.
8
Mounting
the
appliance
For
optional
wall
mounting,
you
need:
•
Screwdriver
•
Drill
with
appropriate
size
bit
•
For
mounting
on
drywall:
•
Two
#6
pan
‐
head
screws,
1
inch
long
(7mm
diameter
head,
25mm
long)
•
Two
wall
anchors
•
For
mounting
on
solid
wood
or
metal:
•
Two
#6
pan
‐
head
wood
or
machine
screws,
1
inch
long
(7mm
diameter
head,
25mm
long)
To
mount
the
appliance
on
the
wall:
1 Drill
two
holes
4.5
inches
(11.5
cm)
apart
in
the
wall
where
you
want
to
mount
the
appliance.
2 If
using
wall
anchors,
insert
a
wall
anchor
into
each
hole.
3 Insert
a
screw
into
each
wall
anchor
(into
each
hole
if
not
using
wall
anchors),
leaving
3/16
inches
(0.45
cm)
of
the
screws
exposed
(including
screw
head).
4 Position
the
appliance
mounting
slots
over
the
screws
and
press
in
and
down
until
the
appliance
is
securely
mounted.
WARNING:
Do
not
mount
the
appliance
on
the
ceiling,
it
is
not
designed
for
secure
ceiling
mounting.
9
Safety
and
regulatory
information
Installing
the
appliance
Install
in
a
location
away
from
direct
sunlight
and
sources
of
heat.
A
maximum
ambient
temperature
of
104º
F
(40º
C)
is
recommended.
Route
cables
away
from
power
lines,
fluorescent
lighting
fixtures,
and
sources
of
noise
such
as
radios,
transmitters,
and
broadband
amplifiers.
The
included
power
cord(s)
are
approved
for
use
only
in
specific
countries
or
regions.
Before
using
a
power
cord,
verify
that
it
is
rated
and
approved
for
use
in
your
location.
Ensure
that
no
water
or
excessive
moisture
can
enter
the
unit.
Allow
unrestricted
airflow
around
the
unit
and
through
the
vents
on
the
side
of
the
unit.
A
minimum
of
1
inch
(25.44mm)
clearance
is
recommended.
Consideration
must
be
given
to
the
connection
of
the
equipment
to
the
supply
circuit.
Appropriate
consideration
of
equipment
nameplate
ratings
must
be
used
when
addressing
this
concern.
Do
not
overload
the
circuit.
This
equipment
is
not
intended
for
use
at
workplaces
with
visual
display
units,
in
accordance
with
§2
of
the
German
ordinance
for
workplaces
with
visual
display
units.
To
avoid
incommoding
reflections
at
visual
display
workplaces
this
device
must
not
be
placed
in
the
direct
field
of
view.
Lithium
battery
warning
The
Lithium
Battery
used
in
the
SonicWall
security
appliance
may
not
be
replaced
by
the
user.
Return
the
SonicWall
security
appliance
to
a
SonicWall
‐
authorized
service
center
for
replacement
with
the
same
or
equivalent
type
recommended
by
the
manufacturer.
If,
for
any
reason,
the
battery
or
SonicWall
security
appliance
must
be
disposed
of,
do
so
following
the
battery
manufacturer's
instructions.
Cable
connections
All
Ethernet
and
RS232
(Console)
cables
are
designed
for
intra
‐
building
connection
to
other
equipment.
Do
not
connect
these
ports
directly
to
communication
wiring
or
other
wiring
that
exits
the
building
where
the
SonicWall
appliance
is
located.
Power
supply
information
If
the
power
supply
is
missing
from
your
SonicWall
product
package,
please
contact
SonicWall
Technical
Support
at
https://support.sonicwall.com/contact
‐
support
for
a
replacement.
This
product
should
only
be
used
with
a
UL
listed
power
supply
marked
“I.T.E.
LPS”
with
an
output
rated
12V
DC,
minimum
2.0
A,
Tma:
minimum
40
degree
C.
WARNING:
For
your
safety,
follow
all
instructions
listed
in
this
section.
EU
and
EFTA
This
device
is
approved
for
use
in
EU
member
states
and
EFTA
countries
as
shown
on
the
appliance
label.
Declaration
of
conformity
A
“Declaration
of
Conformity”
in
accordance
with
the
directives
and
standards
has
been
made
and
is
on
file
at
SonicWall
International
Limited,
City
Gate
Park,
Mahon,
Cork,
Ireland.
CE
declarations
can
be
found
online
at
https://support.sonicwall.com/
.
台灣
RoHS
限用物質含有情況標示資訊請參考下列網址
:
https://support.sonicwall.com
.
操作說明
:
Verwarnung
Weitere
hinweise
zur
montage
Wählen
Sie
für
die
Montage
einen
Ort,
der
keinem
direkten
Sonnenlicht
ausgesetzt
ist
und
sich
nicht
in
der
Nähe
von
Wärmequellen
befindet.
Die
Umgebungstemperatur
darf
nicht
mehr
als
40
°C
betragen.
Führen
Sie
die
Kabel
nicht
entlang
von
Stromleitungen,
Leuchtstoffröhren
und
Störquellen
wie
Funksendern
oder
Breitbandverstärkern.
Das
im
Lieferumfang
enthaltene
bzw.
die
im
Lieferumfang
enthaltenen
Netzkabel
sind
nur
SOHO
W
(RM:
APL41
‐
0BA)
RF
Transmitter
Bands
and
Power
Frequency
Band
Maximum
Radio
‐
Frequency
Power
Transmitted
MHz
dBm
EIRP
2412
‐
2472
18.96
5180
‐
5240
22.09
5260
‐
5320
21.81
5500
‐
5700
23.47
NOTE:
Additional
regulatory
notifications
and
information
for
this
product
can
be
found
online
at:
https://support.sonicwall.com/
輸入產品型號並搜尋
選擇
Technical
Documentation
選擇
Safety
and
Regulatory
Reference
Guide
Download
this
document
下載此文件
für
die
Verwendung
in
bestimmten
Ländern
und
Regionen
zugelassen.
Überprüfen
Sie
bitte
vor
der
Verwendung
eins
Netzkabels,
ob
es
für
die
Verwendung
in
Ihrem
Land
oder
Ihrer
Region
zugelassen
ist
und
den
geforderten
Normen
entspricht.
Stellen
Sie
sicher,
dass
das
Gerät
vor
Wasser
und
hoher
Luftfeuchtigkeit
geschützt
ist.
Stellen
Sie
sicher,
dass
die
Luft
um
das
Gerät
herum
zirkulieren
kann
und
die
Lüftungsschlitze
an
der
Seite
des
Gehäuses
frei
sind.
Hier
ist
ein
Belüftungsabstand
von
mindestens
26
mm
einzuhalten.
Prüfen
Sie
den
Anschluss
des
Geräts
an
die
Stromversorgung,
damit
der
Überstromschutz
sowie
die
elektrische
Leitung
nicht
von
einer
eventuellen
Überlastung
der
Stromversorgung
beeinflusst
werden.
Prüfen
Sie
dabei
sorgfältig
die
Angaben
auf
dem
Aufkleber
des
Geräts.
Überlasten
Sie
nicht
den
Stromkreis.
Dieses
Gerät
ist
nicht
zur
Verwendung
an
Arbeitsplätzen
mit
visuellen
Anzeigegeräten
gemäß
§
2
der
deutschen
Verordnung
für
Arbeitsplätze
mit
visuellen
Anzeigegeräten
vorgesehen.
Um
störende
Reflexionen
am
Bildshirmarbeitsplatz
zu
vermeiden,
darf
dieses
Produkt
nicht
im
unmittelbaren
Gesichtsfeld
platziert
verden.
Verwarnung
hinweis
zur
lithiumbatterie
Die
in
der
Internet
Security
Appliance
von
SonicWall
verwendete
Lithiumbatterie
darf
nicht
vom
Benutzer
ausgetauscht
werden.
Zum
Austauschen
der
Batterie
muss
die
SonicWall
in
ein
von
SonicWall
autorisiertes
Service
‐
Center
gebracht
werden.
Dort
wird
die
Batterie
durch
denselben
oder
entsprechenden,
vom
Hersteller
empfohlenen
Batterietyp
ersetzt.
Beachten
Sie
bei
einer
Entsorgung
der
Batterie
oder
der
SonicWall
Internet
Security
Appliance
die
diesbezüglichen
Anweisungen
des
Herstellers.
Verwarnung
kabelverbindungen
Alle
Ethernet
‐
und
RS232
‐
C
‐
Kabel
eignen
sich
für
die
Verbindung
von
Geräten
in
Innenräumen.
Schließen
Sie
an
die
Anschlüsse
der
SonicWall
keine
Kabel
an,
die
aus
dem
Gebäude
herausgeführt
werden,
in
dem
sich
das
Gerät
befindet.
Informationen
zur
stromversorgung
Wenn
die
Stromversorgung
von
der
SonicWall
‐
Produktpaket
fehlt,
wenden
SonicWall
den
Technischen
Support
unter
https://support.sonicwall.com/contact
‐
support
.
Dieses
Produkt
sollte
nur
mit
einem
für
den
Europäischen
Markt
genehmigten
Netzteil
mit
dem
Logo
"I.T.E.
LPS"
und
einer
Ausgangsleistung
von12
VDC,
mind.
2.0 A,
Tma:
mind.
40
Grad
C,
betrieben
werden.