Sonic Frontiers PHONO 1 PHONOSTAGE Operating Manual Download Page 10

7

If the PHONO 1 Phono Stage is not functioning properly, please
check each of the following:

1.

Check that the AC Detachable Power Cord is plugged into

the Phono Stage’s Detachable Power Cord Socket (D) and is
connected to a 

live

source of AC power. For instance, if using a

power bar, check that the bar is turned on.

2.

Be sure that the Power Switch (C) is in the “ON” position.

3.

Check that input & output connections are correct.

4.

Ensure that the phono stage is not in MUTE mode, or still in

the 40 second warm-up/turn-on cycle.

5.

Check that the AC Line Fuse inside the PHONO 1 chassis is

good. Be sure to

first

unplug the AC Detachable Power Cord

from the chassis rear before removing chassis covers to check the
fuse. For the fuse location see figure 6. To remove the fuse, sim-
ply push down and turn counter-clockwise the fuse holder and
remove the fuse. If the fuse has blown, the thin metal conductor will
have melted and the glass may appear “smoked”. If the fuse has
blown, replace with a fuse of the same type and rating (See specifi-
cations for fuse ratings).

7 .

Check to be sure that all the tubes are correctly and firmly seat-

ed in their tube sockets and that all nine contact pins are inserted
in each socket (i.e. no pins are bent over). Verify that an orange
glow (tube filament) is visible from inside of each tube when the
unit is on.

8.

If you are still experiencing any difficulty with your PHONO 1

Phono Stage, contact your dealer or distributor for assistance.

REPLACEMENT OF THE TUBES

Sonic Frontiers strongly discourages non-factory replacement of
the tubes. The tubes supplied are measured, selected, and
matched in pairs - channel to channel and triode 
section to triode section - for optimum performance.

Problems arising from non-SFI supplied tubes will not be covered
under warranty.

If replacement tubes are needed, desired or required contact
Sonic Frontiers for assistance.

TROUBLE SHOOTING

W A R N I N G

D I S C O N N E C T the  AC  Detachable  Power Cord
from  the  Phono  1  before  beginning 
t r o u b l e s h o o t i n g .

Figure 6

- The Fuse in the Phono 1 is located in the right rear 

corner of the phono stage chassis.

Fuse

Summary of Contents for PHONO 1 PHONOSTAGE

Page 1: ...SONIC PHONO 1 PHONO STAGE FRONTIERS OPERATING MANUAL ...

Page 2: ... to read this manual carefully and follow these instructions in order to keep it looking operating and sounding its best 2790 Brighton Road Oakville Ontario Canada L6H 5T4 Telephone 905 829 3838 Facsimile 905 829 3033 Sonic Frontiers can be reached from 9 00 a m to 5 00 p m Eastern Standard Time or 24 hours a day by facsimile E M a i l S F I s o n i c f r o n t i e r s c o m W e b S i t e h t t p ...

Page 3: ... 1 Operation Connection and Control Diagrams 2 Control and Connection Functions 3 Phono Stage Set up 4 Tube Insertion 4 Chassis Placement 4 Connecting External Equipment 5 Power Connections 6 Powering On and Startup Procedures 6 Trouble Shooting 7 Tube Replacement 7 Fuse Location 7 Safety Instructions 8 Warranty 8 Technical Overview 9 Technical Specifications 9 This symbol is intended to alert the...

Page 4: ...e shipped in the future the original box is the best means for the protection and safety of the phono stage during transportation Here is a chart listing what you will find in the box Tube Complement 4 6922 E88CC Phillips Screwdriver 1 Screws 18 Power Cord 1 Cotton Gloves 1 pair Extra Fuses 2 PHONO 1 Phono Stage 1 Phono Stage Top Cover 1 Warranty Card 1 Operating Manual 1 If after your inspection ...

Page 5: ...2 OPERATION CONNECTIONS AND CONTROL FUNCTIONS PHONO 1 FRONT PANEL A B D E F C PHONO 1 REAR PANEL Figure 1 PHONO 1 Front Panel Figure 2 PHONO 1 Rear Panel H G ...

Page 6: ... PANEL D Detachable Power Cord Socket Plug the supplied power cord female end into this inlet and after checking that the power switch C is in the out position plug the other male end into a suitable AC wall outlet E Left Right RCA Output Jacks These are connected with a suitable length of interconnect to an appropriate input on a line level preamplifier The top jack is the left and the lower is t...

Page 7: ... for the remaining tubes V2 tube to the V2 tube socket V3 tube to the V3 tube socket V4 tube to the V4 tube socket 6 Once all the tubes are installed it is now necessary to choose a setting for the CUE MUTE function This is an internal adjust ment see figure 5 for switch location The setting of this switch will depend upon whether the line level preamplifier has a conve niently located mute switch...

Page 8: ... on internal terminals provided on the rear panel printed circuit assembly To select a loading value it is necessary to refer to the position number on the loading switch s G The values are as follows pF picofarads X 00001 K ohms X1000 Position 1 10 ohms RL1 and RL2 Position 2 100 ohms RL3 and RL4 Position 3 1K ohm RL5 and RL6 Position 4 10K ohm RL7 and RL8 Position 5 47pF CL1 and CL2 Position 6 4...

Page 9: ...ection or call your dealer or our Technical Support representative at 905 829 3838 for assistance POWERING ON STARTUP PROCEDURES SHUTTING OFF POWER When shutting off power from the phono stage it is good practice to mute and then turn off the line level preamplifier first before switching off the phono stage Following this procedure will ensure that no transient pulse will reach the power amplifie...

Page 10: ...If the fuse has blown replace with a fuse of the same type and rating See specifi cations for fuse ratings 7 Check to be sure that all the tubes are correctly and firmly seat ed in their tube sockets and that all nine contact pins are inserted in each socket i e no pins are bent over Verify that an orange glow tube filament is visible from inside of each tube when the unit is on 8 If you are still...

Page 11: ...ITED FIVE YEAR WARRANTY Sonic Frontiers Inc warrants to the purchaser that each PHONO 1 is free of manufacturing defects for a period of five 5 years from the date of purchase This five 5 year limited non transfer able warranty excludes all vacuum tubes which we warrant for a period of twelve 12 months To receive this warranty the original purchaser must complete and mail to Sonic Frontiers within...

Page 12: ...at 1kHz The circuit topology is non invert ing and uses a single high quality J Fet for the input amplifier and a special series amplifier for the second amplifying stage In order to provide a low output impedance a cathode follower is used after the second stage transforming the high output impedance from the second stage to a lower output impedance suitable for driving any preamplifier with a re...

Reviews: