background image

               

                SM1410C    Us er Ma nual                   

http://www.sonbus.com/ 

Sha nghai Son

best Industrial Co., Ltd                                                                             Page4

 

information. For example, after the device is powered on, the reported message is as follows: 01 25 01 05 

D1 80. 

Frame ID 

  device 

address 

function code 

current frame 

ID 

current rate 

CRC16 

00 00 

01 

25 

00 01 

05 

D1 80 

        In the response frame, 01 indicates that the current frame ID is 00 01, and the speed rate value 05 

indicates that the current rate is 50 kbps, which can be obtaine d by looking up the table. 

        Disclaimer 

        This document provides all information about the product, does not grant any license to intellectual 

property, does not express or imply, and prohibits any other means of granting any intellectual property 

rights, such as the statement of sales terms and conditions of this product, other issues. No liability is 

assumed. Furthermore, our company makes no warranties, express or implied, regarding the sale and use 

of this product, including the suitability for the specific use of the product, the marketability or the 
infringement liability for any patent, copyright or other intellectual property rights, etc. Product 

specifications and product descriptions may be modified at any time without notice.  

        Contact Us 

        Company: Shanghai Sonbest Industrial Co., Ltd   

        Address:Building 8,No.215 North east road,Baoshan District,Shanghai,China  
        Web: http://www.sonbest.com  

        Web:    http://www.sonbus.com   

        SKYPE:  soobuu   

        Email: [email protected] 

        Tel: 86-021-51083595 / 66862055 / 66862075 / 66861077 
 

Summary of Contents for SM1410C

Page 1: ... access to PLC DCS and other instruments or systems for monitoring temperature humidity state quantities The internal use of high precision sensing core and related devices to ensure high reliability and excellent long term stability can be customized RS232 RS485 CAN 4 20mA DC0 5V 10V ZIGBEE Lora WIFI GPRS and other output methods Technical Parameters Technical parameter Parameter value Brand SONB...

Page 2: ...e figure above The basic format and composition of the standard frame are as follows As shown in the table 位 7 6 5 4 3 2 1 0 Byte 1 FF FTR X X DLC 3 DLC 2 DLC 1 DLC 0 Byte 2 ID 10 ID 9 ID 8 ID 7 ID 6 ID 5 ID 4 ID 3 Byte 3 ID 2 ID 1 ID 0 x x x x x Byte 4 d1 7 d1 6 d1 5 d1 4 d1 3 d1 2 d1 1 d1 0 Byte 5 d2 7 d2 6 d2 5 d2 4 d2 3 d2 2 d2 1 d2 0 Byte 6 d3 7 d3 6 d3 5 d3 4 d3 3 d3 2 d3 1 d3 0 Byte 7 d4 7 ...

Page 3: ...ng 01 06 01 02 61 88 The format is as shown in the table below Frame ID Set Address Function id source frame ID current frame ID CRC16 00 00 01 06 01 02 61 88 The command will not respond correctly The following is the command and reply message to change the Set Address to 2 3 Change device rate You can use the master station to reset the device rate through commands The range of the rate number i...

Page 4: ...mply and prohibits any other means of granting any intellectual property rights such as the statement of sales terms and conditions of this product other issues No liability is assumed Furthermore our company makes no warranties express or implied regarding the sale and use of this product including the suitability for the specific use of the product the marketability or the infringement liability...

Reviews: