background image

8

S R   2 - 1 2 5   T W O - C H A N N E L   A M P L I F I E R   I N S T R U C T I O N   M A N U A L

Protection Circuitry and LEDs

The  SR  2-125  amplifiers  have  a  multi-stage  protection  system  to 
prevent damage to your amplifier and speakers.

SR 2-125 Amplifier Channel Protection

If a channel encounters a short-circuit or an extremely low impedance 
this will cause the affected channel outputs to automatically mute. 
The output of the affected channel will remain muted until the fault 
has been corrected. Only the affected channels output will mute, all 
other channels will continue to operate normally.

SR 2-125 Amplifier Channel Protection Indication

On the front panel of the SR 2-125 amplifiers are dual color LEDs 
that  illuminate  to  indicate  the  current  operating  status  of  each 
amplifier channel. 

When  the  LED  blinks  red  this  is  an  indication  that  the  channel  is 
being overdriven.

When the LED lights are solid red this is an indication the amplifier 
is  in  protect  mode.  While  in  protect  mode  the  LED  lights  will 
periodically light green to retest the output to determine if the short 
has been removed. Protect mode could be caused by a short in the 
wire, overheating of the amplifier or possibly an internal problem 
with the amplifier.

IMPORTANT:  ALLOWING  THE  AMPLIFIER  TO  OPERATE  WITH 
ONE  OR  MORE  CHANNELS  IN  PROTECT  MODE  FOR  AN 
EXTENDED PERIOD OF TIME CAN DAMAGE THE AMPLIFIER.

SR 2-125 Amplifier Power Supply Protection

The amplifier also has protection for the power supply. If the power 
supply  heat  sink  temperature  exceeds  the  design  maximum  the 
protection circuit will activate disconnecting all channel outputs. This 
is indicated by a blinking light on the front panel power switch.

IMPORTANT:  ANY  TIME  THE  PROTECTION  CIRCUITS  ARE 
TRIGGERED,  UNPLUG  THE  AMPLIFIER’S  POWER  CORD  FROM 
THE WALL OUTLET BEFORE TROUBLESHOOTING.

Rack Ear Installation SR 2-125

The SR 2-125 amplifier ships with two long rack ears for when the 
amplifier is to be used alone in a 1U space. Unscrew the four Phillips 
head screws (M4 x 0.7 pitch x 10mm long) found on each side of 
the left and right forward section of amplifier. Use these screws to 
connect the included rack ears to the amplifier (see Figure 12).

FIGURE 12: RACK EAR INSTALLATION SR 2-125

SIDE VIEW RIGHT

FRONT VIEW

Amplifier Stacking

The  SR  2-125  amplifier  is  capable  of  being  directly  stacked  with 
the feet removed (see Figure 14) for use in low to moderate output 
applications.  For  high-output  applications,  it  is  recommended  to 
leave at least 1U space between amplifiers for increased ventilation. 
It  is  not  recommended  to  stack  more  than  three  amplifiers  high 
without spacing.

Shelf Mounting

If  shelf  mounting,  attach  the  four  included  feet  by  screwing  them 
into the threaded openings, no tool is required. 

To  place  two  SR  2-125  amplifiers  in  a  single  rack  unit  order:  
Rack Mount Bracket for SR 2-125 SKU# 93098 (see Figure 13).

FIGURE 14: STACKED CONFIGURATION (3) SR 2-125

FIGURE 13: RACK MOUNT BRACKET FOR (2) SR 2-125

FRONT VIEW

FRONT VIEW

Summary of Contents for SR 2-125

Page 1: ...SR 2 125 TWO CHANNEL AMPLIFIER INSTRUCTION MANUAL 33 7575 05 24 16...

Page 2: ...U C T I O N M A N U A L TABLE OF CONTENTS Safety 1 Introduction Box Contents 3 Front Panel Rear Panel 4 Amplifier Power Requirement Chart 6 Connections and Volume Level Controls 7 Protection Circuitry...

Page 3: ...e canned air or wipe the amplifier with a soft cloth Do not use solvents as they may damage the amplifier 12 Non use periods Unplug the amplifier s power cord from the outlet when the amplifier will b...

Page 4: ...pareil a t endommag pour quelque raison que ce soit et par exemple si le c ble d alimentation secteur ou sa prise sont endommag s si du liquide a p n tr l int rieur de l appareil ou un objet y est tom...

Page 5: ...r place any object on or against the amplifier Never operate the amplifier on a carpeted surface as this will compromise ventilation When the amplifier is installed in any cabinet the front or back mu...

Page 6: ...TWO CHANNEL AMPLIFIER FRONT PANEL SR 2 125 Front Panel 1 Illuminated Power Button 2 Power Active Protection Indicator LED 3 Recessed Volume Level Control SR 2 125 Rear Panel 4 L R Line In Coax Toslink...

Page 7: ...e controls that will adjust the output and turn on volume The amplifier must be powered on to make these adjustments Rear Panel Inputs The SR 2 125 amplifier has analog coax and toslink LINE INPUTS an...

Page 8: ...FOR CONTINUED PROTECTION AGAINST FIRE REPLACE THE FUSE WITH ONLY THE SAME TYPE AND RATING Source Connections Selection SR 2 125 There are two options when connecting audio inputs to the SR 2 125 ampl...

Page 9: ...odate up to 12 gauge wire see Figure 9 NOTE ALWAYS CHECK LOCAL BUILDING CODES BEFORE INSTALLING WIRE IN WALLS OR CEILINGS IMPORTANT USE CAUTION WHEN SETTING VOLUME LEVELS EITHER ON THE AMPLIFIER OR AN...

Page 10: ...mplifier Power Supply Protection The amplifier also has protection for the power supply If the power supply heat sink temperature exceeds the design maximum the protection circuit will activate discon...

Page 11: ...RATING Audio Auto On OFF When the Audio Auto On switch is in the OFF position the amplifier will enter Sleep Mode after 15 minutes without an audio signal present on any of the channels When an audio...

Page 12: ...dle 26 5 Watts standby 0 3 Watts Power Consumption 220V AC 8 ohms sinewave full power 300 Watts all channels driven 4 ohms sinewave full power 314 5 Watts all channels driven 8 ohms sinewave 1 8 power...

Page 13: ...UENTIAL INCIDENTAL ECONOMIC PROPERTY BODILY INJURY OR PERSONAL INJURY DAMAGES ARISING FROM THE PRODUCT ANY BREACH OF THIS WARRANTY OR OTHERWISE This warranty statement gives you specific legal rights...

Reviews: