Sonance SONAMP Sonamp 1230 User Manual Download Page 12

13

ZONE

1

KITCHEN

+ PAGING

ZONE

2

DINING

ROOM

ZONE

3

FAMILY

ROOM

T4000

T4000

T4000

KSU TELEPHONE

PAGE

PAGE

OUT

OUT

FIXED

TAPE OUTPUT

LEFT

RIGHT

INPUT SOURCE

ZONE

1•2•3•4•5

HOUSE SYSTEM
FIXED OUT

LEFT

RIGHT

VIDEO1

VIDEO2

CD

AUX

PHONO

VARIABLE

PRE OUTPUT

LEFT

RIGHT

INPUT SOURCE

ZONE

6

BEDROOM
VARIABLE OUT

ZONE

6

MASTER

BEDROOM

Virtuoso

ZONE

5a

BATH

M10R

M10R

ZONE

5b

CLOSET

IR CONTROL

PAGING

PAGING

WALL MOUNT

IR Receiver

VOLUME

VOLUME

VOLUME

VOLUME

VOLUME

VOLUME

+

+

+

+

+

+

+

+

+

BRIDGED

NORMAL

8

 Min.

8

 Min.

8

 Min.

8

 Min.

8

 Min.

8

 Min.

BRIDGED

NORMAL

BRIDGED

NORMAL

BRIDGED

NORMAL

BRIDGED

NORMAL

BRIDGED

NORMAL

CHANNEL

1

CHANNEL

2

CHANNEL

3

CHANNEL

4

CHANNEL

5

CHANNEL

6

CHANNEL

7

CHANNEL

8

CHANNEL

9

CHANNEL

10

CHANNEL

11

CHANNEL

12

DIRECT

LEFT

RIGHT

AUX

DIRECT

LEFT

RIGHT

AUX

DIRECT

LEFT

RIGHT

AUX

DIRECT

LEFT

RIGHT

AUX

DIRECT

LEFT

RIGHT

AUX

DIRECT

LEFT

RIGHT

AUX

DIRECT

LEFT

RIGHT

AUX

DIRECT

LEFT

RIGHT

AUX

DIRECT

LEFT

RIGHT

AUX

DIRECT

LEFT

RIGHT

AUX

DIRECT

LEFT

RIGHT

AUX

DIRECT

LEFT

RIGHT

AUX

BRIDGED

BRIDGED

BRIDGED

BRIDGED

BRIDGED

BRIDGED

CH. 1

CH. 2

CH. 3

CH. 4

CH. 5

CH. 6

CH. 7

CH. 8

CH. 9

CH. 10

CH. 11

CH. 12

BUS INPUT

BUS OUTPUT

LEFT

RIGHT

AUX

LEFT

RIGHT

AUX

GROUND

LIFT

ON

OFF

INPUT

5-24V AC/DC

AUTO-ON

OUTPUT

12VDC

1200VA

F 10A T 250V

120V

˜ 

60Hz

˜ 

FUSE

TRIGGER 

MODE

AUTO-ON

EXTERNAL VOLTAGE

BYPASS

Caution: For Continued Protection Against Fire Hazard Use Only Same Type And Rating Fuses. Disconnect Power Supply Before Changing Fuse. Do Not Expose This Unit To Rain Or Moisture. No User Servicable Parts Inside. See Operating Manual Before Using.
Mise en garde: Afin d' éviter toute possibilité d' incendie, n´ utiliser que le même type de fusibles. Débrancher  l´appareil avant de changer les fusibles. Ne pas exposer cet appareil å l ire ou å l´humidité. Ne pas ouvrir l´appareil. Lire attentivement la notice avant utilisation.

SONAMP

®

 1230

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

SN:

SONANCE

SAN CLEMENTE, CA 

92672-7531

FUSE

FUSE

VOLUME

VOLUME

VOLUME

VOLUME

VOLUME

VOLUME

BRIDGED

NORMAL

BRIDGED

NORMAL

BRIDGED

NORMAL

BRIDGED

NORMAL

BRIDGED

NORMAL

BRIDGED

NORMAL

DIRECT

LEFT

RIGHT

AUX

DIRECT

LEFT

RIGHT

AUX

DIRECT

LEFT

RIGHT

AUX

DIRECT

LEFT

RIGHT

AUX

DIRECT

LEFT

RIGHT

AUX

DIRECT

LEFT

RIGHT

AUX

DIRECT

LEFT

RIGHT

AUX

DIRECT

LEFT

RIGHT

AUX

DIRECT

LEFT

RIGHT

AUX

DIRECT

LEFT

RIGHT

AUX

DIRECT

LEFT

RIGHT

AUX

DIRECT

LEFT

RIGHT

AUX

CH. 1

CH. 2

CH. 3

CH. 4

CH. 5

CH. 6

CH. 7

CH. 8

CH. 9

CH. 10

CH. 11

CH. 12

Caution: For Continued Protection Against Fire Hazard Use Only Same Type And Rating Fuses. Disconnect Power Supply Before Changing Fuse. Do Not Expose This Unit To Rain Or Moisture. No User Servicable Parts Inside. See Operating Manual Before Using.
Mise en garde: Afin d' éviter toute possibilité d' incendie, n´ utiliser que le même type de fusibles. Débrancher  l´appareil avant de changer les fusibles. Ne pas exposer cet appareil å l ire ou å l´humidité. Ne pas ouvrir l´appareil. Lire attentivement la notice avant utilisation.

BRIDGED

NORMAL

DIRECT

LEFT

RIGHT

AUX

INDICATED

DIP SWITCH

POSITION

(ON POSITION)

INDICATED

SLIDE SWITCH

POSITION

(BRIDGED POSITION)

VC60RX

Volume Control

IR

D8001

FLAT

TREBLE

MID

PN.33-0917

D8001

PN.33-0916

TREBLE

LIVE
ROOM

DEAD
ROOM

MID

SEE OWNER'S MANUAL
FOR ADDITIONAL SETTINGS

HI IMP

REDUCE VOLUME BEFORE ADJUSTING SWITCHES

P L A T I N U M

IR

D8001

FLAT

TREBLE

MID

PN.33-0917

D8001

PN.33-0916

TREBLE

LIVE
ROOM

DEAD
ROOM

MID

SEE OWNER'S MANUAL
FOR ADDITIONAL SETTINGS

HI IMP

REDUCE VOLUME BEFORE ADJUSTING SWITCHES

P L A T I N U M

VC30RX

Volume Control

ZONE

4a

FOYER

M10R

M10R

ZONE

4b

HALL

VC30RX

Volume Control

VC60RX

Volume Control

VC60RX

Volume Control

VC60SX

Volume Control

VC60SX

Volume Control

Figure 5 Multiple Amplifier / Home Theater/Multiple Zone+Paging

Summary of Contents for SONAMP Sonamp 1230

Page 1: ...n to cords at plugs conve nience receptacles and the point where they exit from the appliance 14 Cleaning The appliance should be cleaned only as recommended by the manufacturer 15 Non Use Periods The...

Page 2: ...e Silver MediaLinQ OFC Interconnects Speaker wires These may be unterminated tinned bare wire at connections or spade banana or pin connectors Gold plated connectors are preferred to resist oxidation...

Page 3: ...Fire Hazard Use Only Same Type And Rating Fuses Disconnect Power Supply Before Changing Fuse Do Not Expose This Unit To Rain Or Moisture No User Servicable Parts Inside See Operating Manual Before Us...

Page 4: ...red Place tape over the VC hole to prevent tampering Power Trigger Controls The Sonamp 1230 may be automatically activated by an input signal low voltage trigger or manual pushbutton It also provides...

Page 5: ...o speakers one pair of speakers per room The factory default rear panel DIP switches and toggles are set for this application This is a single zone system Note that each room may have a volume control...

Page 6: ...urn on as well as feeding video to three TVs located in zones two five andsix Eachof thesixzonesiscontrolledbyaSonanceNavigator Master keypad The source components are controlled by the Harbor s Commo...

Page 7: ...the package Ship the packaged unit to Technical Assistance Department Sonance 212 Avenida Fabricante San Clemente CA 92672 7531 WARRANTY COVERAGE USA ONLY If within one 1 year from the date shown on t...

Page 8: ...ng Manual Before Using Mise en garde Afin d viter toute possibilit d incendie n utiliser que le m me type de fusibles D brancher l appareil avant de changer les fusibles Ne pas exposer cet appareil l...

Page 9: ...nual Before Using Mise en garde Afin d viter toute possibilit d incendie n utiliser que le m me type de fusibles D brancher l appareil avant de changer les fusibles Ne pas exposer cet appareil l ire o...

Page 10: ...Operating Manual Before Using Mise en garde Afin d viter toute possibilit d incendie n utiliser que le m me type de fusibles D brancher l appareil avant de changer les fusibles Ne pas exposer cet appa...

Page 11: ...de changer les fusibles Ne pas exposer cet appareil l ire ou l humidit Ne pas ouvrir l appareil Lire attentivement la notice avant utilisation SONAMP 1230 CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN S...

Page 12: ...it Ne pas ouvrir l appareil Lire attentivement la notice avant utilisation SONAMP 1230 CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN SN SONANCE SAN CLEMENTE CA 92672 7531 FUSE FUSE VOLUME VOLUME VOLUME V...

Reviews: