background image

ZT09 Long Life Tracker User Manual 

 

Web: www.sonaltrack.com 

Email: [email protected] 

Ph: 8613857402537 

4.6 Time Zone Settings 

GMT,<A>,<B>,<C> 

Set time zone:   
A: E or W, represent east and west. 
B: 0 ~ 12 time zone   
C: half time zone 
Example: GMT,E,8,0# 

USELOCALTZ,1 

Associated time zone: The reported data time is 
synchronized to the set time zone. 

USELOCALTZ,0 

Non-associated time zone: The default reported data 
time is fixed to the time zone of UTC + 8 

 

4.7 Common Query Commands 

 

VERSION# 

Query software version 

PARAM# 

Query the device parameters 

STATUS# 

Query working status 

123 

Query the device address, the device will force a 
position data to be reported to the server after 
receiving the 123 command. 

FACTORY 

Restore factory settings, IP and domain names will   
not restored. 

RESET# 

Device restart. 

 

Summary of Contents for ZT09

Page 1: ...g commands 6 4 1 Reporting logic on different working mode 6 4 2 Application Notes on Low Power Alarm 7 4 3 Light Detected Alarm Description 8 4 4 Vehicle Collision Alarm Parameter setting 8 Use to adjust parameters according to actual installation and use 8 4 5 Vehicle Acceleration Deceleration and Sharp Turn Parameter setting 8 4 6 Time Zone Settings 10 4 7 Common Query Commands 10 4 8 Common Se...

Page 2: ...1A 5V l Support reset button you can restart the device without disassembling l Support multiple working modes regular reporting periodic reporting real time tracking intelligent tracking refer to 4 1 l Support low power alarm refer to 4 2 l Built in rear light detection alarm function or front light detection optional refer to 4 3 l Support collision alarm and flip alarm refer to 4 4 l Support da...

Page 3: ...A MODE 21 sleep current 3mA MODE1 2 3 21 normal working current 60mA Standby Time MODE 1 Daily report 600 days MODE 3 Hourly report 30 days MODE 21 Report 2 hours per day 30 days MODE 2 Real time positioning 4 days Dimension 68 48 26mm Weight 100g Working Temperature 20 C 80 C Humidity 5 95 Frequency Bands 4G LTE FDD B1 B2 B3 B4 B5 B7 B8 B20 B28 B66 4G LTE TDD B38 B40 B41 2G GSM GPRS EDGE 850 900 ...

Page 4: ...e process Remove SIM card cover Insert the SIM card to power on the device The device works in MODE 21 intelligent tracking mode by default LED status 1 LED flashing slowly Registered to the network 2 LED flashing quickly Connected to the server 3 LED is always on GPS fixed Open the app login to the system and check the positioning Tap on the menu or send server command to reconfigure the working ...

Page 5: ...ly charged before use It is recommended that a 5V 2A charger to be used to support the fast charging mode The charging time is about 5 hours The use of different chargers will vary The red LED lights up when charging and the green LED lights up when the battery is fully charged The charging cable is a standard Micro USB charging cable 3 3 Manage your device 1 Manage device on WEB visit http www ba...

Page 6: ...POITYPE 0 1 2 0 LBS Report LBS only 1 LBS GPS Priority report to base station GPS will be reported after successful positioning 2 LBS WIFI GPS This device does not support WIFI 2 Parameter clear command MODECNTCLEAR 0 1 0 Auto automatically clear MODE 1 2 parameters after full charge 1 Forcibly clear the reporting times of MODE 1 3 and the working time of MODE 2 21 Note For mode 1 3 each time it i...

Page 7: ... for daily reporting 1 31 Example MODE 1 0800 1314 2 It means device will wake up at 8 00 and 13 14 every 2 days 5 Periodic reporting mode MODE 3 T T 5 1440 The range of T Unit minute T is the gap time for MODE 3 reporting 6 Real time tracking mode MODE 2 T T 5 999 The range or T Unit second Default value 10 The position reporting period when the device is moving 4 2 Application Notes on Low Power...

Page 8: ...e 1 GSENCOL V T C Used to set the sensitivity of collision alarm Default 32 2 3 V 1 255 the higher value the less sensitive T 0 11 the time V keeps C 0 3 the number of interrupts Different vehicles have different parameters It is recommended to set the parameters as follows Motorcycle GSENCOL 128 3 3 Car GSENCOL 48 3 3 4 5 Vehicle Acceleration Deceleration and Sharp Turn Parameter setting 1 Drivin...

Page 9: ...m h in X time range unit S A 1 X 58 A 2 X 29 A 3 X 19 A 4 X 14 A 5 X 11 A 6 X 9 2 GSENDIR D Used to set the coordinate system of the device D 0 15 The default is D 5 the GPS antenna is facing the sky and the cable is facing the rear of the car D 7 GPS antenna is facing the sky wire is facing the front D 4 GPS antenna is facing the sky wire is facing to the left D 6 GPS antenna is facing the sky wi...

Page 10: ...e is synchronized to the set time zone 3 USELOCALTZ 0 Non associated time zone The default reported data time is fixed to the time zone of UTC 8 4 7 Common Query Commands 1 VERSION Query software version 2 PARAM Query the device parameters 3 STATUS Query working status 4 123 Query the device address the device will force a position data to be reported to the server after receiving the 123 command ...

Page 11: ...umber 5 APN name Set APN 6 APN AUTOAPN Set to automatic APN 7 RELAY 0 1 1 Remote control set 0 Remote control clear 8 LED 0 1 Controls whether the LED is always on LED 1 is always on LED 0 is off after five minutes default is 0 5 Cautions 1 Do not short circuit 2 Do not put in fire or heat 3 It is strictly prohibited for users to assemble or disassemble the battery by themselves 4 Do not use outsi...

Reviews: