EH8 Single Phase Digital Voltage/Ampere Meter
                     User

s Manual

KKEH8E01-A/0-1

1.Code Illustration

EH8-

□□□

Features:

B: Range :450V

×

5A

D:Other range

(mm) 8:48H

×

96W

×

100L

EH Series voltage/ampere meter

    E H   S e r i e s   D i g i t a l   Vo l t a g e / A m p e r e   M e t e r

Accuracy : 

±

0.5%F.S

Can measure: voltage, current

Input and output are completely isolated .

With high/low limit settable alarms of voltage / current .

With 4-20mA analog output for voltage / current .

With RS485 communication interface

Modbus RTU communication protocol

Can measure true/effective value .

Menu setting can be operated conveniently, 

For your safety, please read following content carefully before you are using the meter!

Safe Caution

Please read the manual carefully before you use the meter!

 Please comply with the below important points:

Warning

Notice  

  An accident may happen if the operation does not comply with the instruction.

  An operation that does not comply with the instruction may lead to product damage.

The instruction of the symbol in the manual is as below:

An accident danger may happen in a special condition.

Warning

1.A safty protection equipment must be installed or please contact with us for the relative information if the 
   product is used under the circumstance such as nuclear control, medical treatment equipment, automobile,
   train, airplane, aviation, entertainment or safty equipment, etc. Otherwise, it may cause serious loss, fire
   or person injury.
2.A panel must be installed, otherwise it may cause creepage (leakage).
3.Do not touch wire connectors when the power is on, otherwise you may get an electric shock.
4.Do not dismantle or modify the product. If you have to do so, please contact with us first. Otherwise it may
   cause electric shock and fire.
5.Please check the connection number while you connect the power supply wire or input signal, otherwise it may
   cause fire.

1

.This product cannot be used outdoors. Otherwise the working life of the product will become shorter, or an electric

   shock accident may happen.

2.When you connect wire to the power input connectors or signal input connectors, the moment of the No.20 AWG
   (0.50 mm2) screw tweaked to the connector is 0.74n.m - 0.9n.m. Otherwise the connectors may be damaged or get
   fire. 
3.Please comply with the rated specification. Otherwise it may cause fire after the working life of the product 
   becomes shorter.
4.Do not use water or oil base cleaner to clean the product. Otherwise it may cause electric shock or fire, and 
   damage the product.
5.

This product should be avoid working under the circumstance that is flammable, explosive, moist, under sunshine, 

    heat  radiation and vibration. Otherwise it may cause explosion.

6. 

In this unit it must not have dust or deposit, otherwise it may cause fire or mechanical malfunction.

7. Do not use gasoline, chemical solvent to clean the cover of the product because such solvent can damage it.
    Please use some soft cloth with water or alcohol to clean the plastic cover.

Caution

Dimension

Output function

R: without analog   D:with analog (4-20mA)

Alarm function: A: Without alarm function   B: with one loop of alarm   C: with two loops of alarm

10

Single phase input    18

Single phase input with RS485 communication

Summary of Contents for EH8

Page 1: ...o not touch wire connectors when the power is on otherwise you may get an electric shock 4 Do not dismantle or modify the product If you have to do so please contact with us first Otherwise it may cau...

Page 2: ...V 3A or DC 30V 5A Input impedance Voltage input impedance 2M 450V current input impedance 0 02 when direct input is 0 5A Direct input range Displaying mode CT Measuring accuracy Sampling speed Power s...

Page 3: ...the measured current is higher than 5A LCK Menu lock setting value 000 or 010 when it is 000 the parameters could be modified when it is 010 all the parameters couldn t be modified Ex factory value i...

Page 4: ...elative humidity is below 85 2 It should be adjusted every year 3 Avoid 4 If it is stored for a long time and unused connect on power for more than 4 hours once every 3 months 5 Don t explose it in th...

Page 5: ...1 0x03 0x04 0x00 0x80 0x71 0x43 0x9E 0x7A Meter address Function code Data byte number Data 1 High bit Data 1 Low bit Slave unit abnormal answer Read multi register 1 2 3 8 9 0x01 0x84 0x01 0x82 0xC0...

Page 6: ...mode Ad1 1 0 9 R W Note Note 21 0x0015 2nd alarm mode Ad2 1 0 9 R W 22 0x0016 Analog mode brM 1 0 3 R W 23 0x0017 Menu lock LCK 1 0 255 R W 24 0x0018 Baud rate bAd 1 0 1 R Note Note 25 0x0019 Address...

Page 7: ...AL2 AL1 mA A KV V The program of decimalist float data converts to 4 byte character code as IEEE 754 standards Program of obtaining 16 digits CRC checking code The program of 4 byte character code flo...

Reviews: