EN
Sonesse 30 DCT
10
Copyright
©
2022 SOMFY ACTIVITES SA. All rights reserved.
CAUTION
• The product is intended for being supplied by Class II output of an external
power supply.
• Do not use an extension cord. If the power supply cord is too short, have a
qualified electrician install an outlet near the motorised product.
NOTICE
Sonesse 30 DCT is a dry contact drive. It can’t be controlled with power going
through the setting tool cable.
Connect the drive to the power supply:
▪
Black wire: -
▪
Red wire: +
2.3.2.Wiring of the control point
2.3.2.1.Setting tool or 4 wires switch
(
a
): Up (White/Blue wire)
(
b
): Stop (Blue wire)
(
c
): Down (White/Orange wire)
(
d
): Common (Orange wire).
1
3
4
2
a
c
b
d
a
c
b
d
2.3.2.2.Smoove IB+
(
a
): Up (White/Blue wire) or Down (White/Orange
wire)
(
b
): Up (White/Blue wire) or Down (White/Orange
wire)
(
c
): Common (Orange wire).
1
2
3
a
c
b
2.3.2.3.Wall switch
(
a
): Up (White/Blue wire) or Down (White/Orange
wire)
(
b
): Up (White/Blue wire) or Down (White/Orange
wire)
(
c
): Common (Orange wire).
1
2
3
a
c
b