background image

           Power 1.0 DC Flush installation instructions

Please read this installation guide carefully so that you can ensure 
that the product functions reliably.
Somfy shall not be liable for any defects or damages if these are 
caused by use outside the field of application or the failure to observe 
this installation guide (incorrect installation, incorrect commissioning, 
incorrect operation, etc.).

The Power 1.0 DC Flush power supply is designed to supply power to 24 V DC motors. Due to its small 
dimensions, it can be installed in a surface box or a flush-mounted box. The output voltage is 24 V DC regulated.

1 Safety instructions

To ensure the safety of individuals, it is important to follow these instructions.
Incorrect installation can lead to serious injury.
Attention: Keep these safety instructions.
• Only a qualified person may set up, test, commission and perform troubleshooting on the installation.
• Switch off the voltage to all of the connection lines which are to be installed before working on the installation. 
Remove all lines that are not needed and take out of operation all equipment that is not required for actuation  
with the motor.
• Follow the installation and operating instructions, particularly the safety instructions for the equipment to be 
operated.

2 Technical data

Operating voltage:

230 V~ 50/60 Hz

Output voltage no-load:

24 V DC

Continuous current:

Max. 1.0 A

Temporary current:

1.5 A

Overload switch-off:

100 ms > 1.6 A

Index protection rating:

II

Safety level:

IP 20

Number of motors that 
can be connected:

1

Dimensions H x W X D 
in mm:

51 X 49 X 25

Operating temperature:

-25 °C to + 40 °C

Attention: Installation must take 
place in a flush-mounted box/
pattress box (e.g. 55 mm).

www.somfy.com