1
. CHECK TO EN
S
URE THAT YOUR AWNIN
G
(or other
window
c
overing) I
S
MOVIN
G
IN THE RI
G
HT
DIRECTION.
- After wiring the Phoenix motor, turn
the power on to ensure that the switch
is operating properly.
If not
, turn off the power off, and simply reverse the black and
red (or brown and black) motor leads conneced to the switch.
2.
S
ETTIN
G
THE LIMIT
S
WITCHE
S
.
-
C
heck the arrow directions near the hollow s
q
uare drive shaft
- The UP and DOWN motor limits are set by the two socket
screws located near the manual override hook.
PLease use for this purpose the Allen wrench included with
the motor.
S
etting the “up” po
s
tition
- Press the switch in “up
”
position.
- If the system stop before its up limit, turn the up screw to
“+
”
until necessary.
- If the system does not stop before its up limit, press the
switch in “down
”
direction and turn the up screw to “-
”
.
Repeat this until correct setting is realized.
S
etting the “down” po
s
tition
- Press the switch in “down
”
position.
- If the system stop before its down limit, turn the down screw
to “+
”
until necessary.
- If the system does not stop before its down limit, press the
switch in “down
”
direction and turn the down screw to “-
”
.
Repeat this until correct setting is realized.
-1+
+2-
Common
(white)
Power
Source
(120 AC)
Ground
(green)
Direction 2
(red)
1
2
Direction 2
(red)
Direction 1
(black)
Hot from
source
(black)
Switch Box
-1+
+2-
Common
(white)
Power
Source
(230Vac)
Ground
(green)
Direction 2
(red)
1
2
Direction 2
(black)
Motor common
(blue)
Neutral from
source
Direction 1
(black)
Hot from
source
Neutral from
source
Switch Box
PHOENIX PH 30/
1
4 (
1
20V AC)
PHOENIX PH 50/
1
2 (230V AC)
Bl
ac
k
1: Dire
c
tion
2: Dire
c
tion
Common
Ground
Red
White
Green
PH 30/14
120 VAC
Co
d
e
Brown
1: Dire
c
tion
2: Dire
c
tion
Common
Ground
Bl
ac
k
Blue
Green
PH 50/12
230 VAC
Co
d
e
M
a
intened Ro
c
ker Swit
c
h (prin
c
ess pl
a
te)
1800328
1800329
Moment
a
ry Ro
c
ker Swit
c
h (prin
c
ess pl
a
te)
Suggeste
d
Switches
Cat. n°.v
S
OMFY
S
Y
S
TEM, INC.
reserve the right update, change or
modifiy these instructions without
prior notice
copyright © SOMFY SYSTEM, IN
C
S
OMFY MEXICO
S
.A. De C.V
C
alle 3 No. 47, Loc. E-5
Fracc Ind. Alce Blanco
Nau., Edo. de Mex
C
.P.53370
S
OMFY
S
Y
S
TEM
S
, INC.
47
C
ommerce Drive
C
ranbury, NJ 0
8
512
S
OMFY CANADA
6315 Shawson Drive, Unit # 1
Mississauga, Ontario L5T1J2v
+2-
-1+
-
Sc
rew
1
adju
s
t dire
c
tion
1
-
Sc
rew 2 adju
s
t dire
c
tion 2
Up retra
c
t
s
Down extend
LIMIT
S
WITCH
S
ETTIN
G
4
2/2
- ALL WIRIN
G
MU
S
T BE IN ACCORDANCE WITH N.E.C. AND LOCAL CODE
S
.
- DO NOT WIRE TWO MOTOR
S
TO ONE
S
IN
G
LE POLE
S