2.1.4 Installing the drive/tube assembly
1)
Fit and attach the tube/drive assembly to the end support (
f
) and the drive support (
g
):
Ensure that the drive/tube assembly is secured onto the end bracket. This
prevents the tube/drive assembly from coming out of the end support fixing.
2)
Depending on the type of bracket, screw the adapter onto the motor head.
2.2 WIRING
The Standard NF C 15-100 for electrical installations must be adhered to.
Cables which pass through a metal wall must be protected and insulated using a sheath or sleeve.
Attach cables to prevent any contact with moving parts.
If the drive is used outdoors and if the power supply cable is of the H05-VVF type, run the cable in a UV-resistant duct,
e.g. trunking.
The cable on the Oximo 40 WF RTS cannot be removed. If it is damaged, return the drive to the A
%
er-Sales department.
Always make a loop in the power supply cable to prevent water entering the drive!
Leave the power supply cable to the actuator accessible: it must be easily replaceable.
The cables and connectors must be protected from the roller shutter movement.
Somfy recommends placing the connectors behind the end piece and fixing the cables inside the roller shutter casing.
1)
Wire the 4-pin motor connector (A) to the 4-pin cable Y connector (B).
2)
Wire the 2-pin battery connector (C) to the 2-pin cable Y connector (D).
3)
Wire the 2-pin solar panel connector (E) to the 4-pin cable Y connector (F).
1
1
1)
2)
g
f
h
1
A
B
F
E
D
C
Summary of Contents for Oximo 40 WireFree RTS
Page 1: ...Oximo 40 WirefreeTM RTS Ref 5125049A FR Notice DE Anleitung EN Instructions www somfy com...
Page 2: ......
Page 13: ...13 FR Copyright 2017 Somfy SAS All rights reserved Images non contractuelles...
Page 24: ...24 DE Copyright 2017 Somfy SAS All rights reserved Abbildungen nicht bindend...
Page 35: ...35 EN Copyright 2017 Somfy SAS All rights reserved Images not contractually binding...