4
A. Setting the Intermediate Position
1.
Enter programming mode by pressing the UP and DOWN buttons of a Telis Transmitter simultaneously. The window treatment will respond by jogging UP then
DOWN.
2.
Press and release the UP button then press and release the STOP button. The shade will respond by lowering to its bottom limit.
3.
After the window treatment reaches its lower limit, press and release the UP button on the Telis Transmitter. The shade will begin to raise.
4.
Press the STOP button on the Transmitter when the desired intermediate position is reached. The motor will stop, then respond by jogging UP then DOWN.
5.
The intermediate position can be changed at any time by repeating steps 1 - 4 above.
INTERMEDIATE POSITION
B. Reaching the Intermediate Position
When the motor is at rest, press the STOP button on a Telis Transmitter. The window treatment will lower to its bottom limit and pause. After the programmed run time,
it will raise to the programmed position.
D. Clearing the Intermediate Position
In order to clear the programmed Intermediate Position, a Memory Clear command must be performed.
5
1.
Make sure the window treatment is not at its upper limit. Enter programming mode by pressing the UP and DOWN buttons of a Telis Transmitter simultaneously. The
window treatment will respond by jogging UP then DOWN.
2.
Press and release the UP button 6 times, pausing after each switch press to verify the motor jogs UP. Press and release the STOP button, the shade will respond by
jogging. The Intermediate Position is now disabled.
C. Disabling the Intermediate Position
Changing the Run Time
RUN TIME
1.
Make sure the shade is not at the upper limit. Enter programming mode by pressing the UP and DOWN buttons of a Telis Transmitter simultaneously. The window
treatment will respond by jogging UP then DOWN.
2.
Press and release the UP button 7 times, pausing after each switch press to verify the motor jogs UP. After the seventh jog, press and release the STOP button until
the motor jogs.
3.
Press and release the DOWN button a number of times to select the following run times:
Once for 15 seconds
Twice for 30 seconds
3 times for 1 minute
4 times for 2 minutes
4.
Press and hold the STOP button until the motor jogs, indicating the run time is saved.
5.
To change the run time, simply repeat steps 1 though 4 above.
The motor outputs of the MultiLink Plug-in, upon power-up, will turn on for a period of 2 minutes when activated. In other words, when a direction is activated, the
motor will run for 2 minutes unless a STOP command is given. This run time can be adjusted to 1 minute, 30 seconds or 15 seconds if desired.
MEMORY CLEAR
1.
Enter programming mode by pressing the UP and DOWN buttons of a Telis Transmitter simultaneously. The window
treatment will respond by jogging UP then DOWN.
2.
Press and release the UP button 4 times, pausing after each switch press to verify the motor jogs UP. Press and hold the STOP button until the motor jogs. All
transmitters and functions are now deleted from memory.
3.
Alternately, the memory can be cleared by pressing the Programming button on the MultiLink Plug-in for 7 seconds. The motor will jog twice, once at 2 seconds and
once at 7 seconds. All programmed transmitters and functions are removed from memory.
Make sure the shade is not at its upper limit.
THIS STEP ERASES ALL MEMORIZED TRANSMITTER CHANNELS AND PROGRAMMED FUNCTIONS!
6
TI N