45
Copyright © 2016 Somfy SAS. All rights reserved.
EN
Images not contractually binding
"
The motor can be wired in parallel. In this case, take into
account the maximum load of the switch or controller used.
1
The phases and neutrals of each motor must be
interconnected respectively.
1
Do not use multi-pole cables to control several motors.
Each motor must be connected to its own power cable.
2. 3. SET
$
UP
1
Use universal adjusting cable 9015971 (follow the instructions in the corresponding manual for
connection), or use a non-locking double push-button switch to adjust settings.
Follow the following steps for set-up:
1)
Checking the rotation direction (
§2. 3. 1
)
2)
Setting the end limits (
§2. 3. 2
)
3)
Setting advanced functions (
§2. 3. 3
)
2. 3. 1. Checking the rotation direction
1)
Switch the mains power supply back on.
Press the "Up" button at the control point:
•
If the driven product raises, the wiring is correct, go to end
limits setting step (
§2.3.2
).
•
If the driven product is lowered, go to the next step.
2)
Switch o
ff
the power.
-
Reverse the brown wire and the black wire connected
to the control point.
3)
Switch the power back on.
-
Press the "Up" button to check the direction of rotation.
2. 3. 2. Setting the end limits
"
The procedure used to set the end limits depends on the equipment of the driven product (see table
below).
"
Pressing and holding the "Up" or "Down" buttons causes the driven product to raise or lower
continuously.
"
Pressing the "Up" or "Down" buttons briefly causes the driven product to raise or lower briefly.
Available devices
k
Top stop
l
Heavy load bar
Steps to
performed
-
-
See E1
,
-
See E2
,
,
See E3*
* This step is especially suitable for "ZIP screens" or for any other specific driven product with a heavy
load bar and a top stop.
1
Use universal adjusting cable 9015971 (follow the instructions in the corresponding manual for
connection), or use a non-locking double push-button switch to adjust settings.
1)
2)
3)
ON
ON
OFF
OK
2
OK
k
l
M
M
M
L1
L2
N