background image

CD 1 X 4 P 

Four motors control unit

The 

CD 1 x 4 P 

enables the individual control of 4 x 230 V AC motors. As the 

CD 1 x 4 P

can be

used as local and master control, it is suitable for large and small installations. An additional group
control is no longer necessary with the 

CD 1 x 4 P

The 

CD 1 x 4 P

is suitable for roller shutters, awnings, as for exterior and interior Venetian blinds. 

The slat rotation is adjustable.

General control is activated by IB compatible control units (such as e.g. a timer control, solar
and wind control or façade control) and transferred to all 

CD 1 x 4 P

via the IB low voltage BUS

line.The 4 motors can be operated locally in one group by a local switch. Several push buttons and units can be connected
in parallel.

Two previously recorded intermediate positions can be called-up via an optional button (“IP key”). By connecting a switch, it is
possible to disconnect the automatic mode. All the safety commands, which are activated by the BUS line, have priority even
when the automatic mode is disconnected. The BUS line is powered directly by the 

CD 1 x 4 P

The 

CD 1 x 4 P

can be installed whether surface-mounted, in false floors, partition walls or false ceilings, or in an electrical

cabinet with a special DIN rail adapter.

ATTENTION : observe precaution for handling electrostatic discharge sensitive devices. 
The printed circuit board is packed in an anti-static protective covering upon delivery. 

INSTALLATION

guide

Ref. GMD021010

1

Installation

Assembly, testing, commissioning and trouble-shooting of the unit may only be carried out by a qualified electrician (respect the local
electrical standard). Disconnect all the connection wires which are to be fitted. Take the necessary safety measures to prevent uninten-
tional reconnection. 
Proper functioning can only be guaranteed by expert installation and sufficient power supply.

1.1

Assembly / Wiring

CD 1 x 4 P6 for the DIN rail

When fitting the CD 1 x 4 P6 board on 35 mm DIN rail, two DIN rail adapters are used.
Put the board on the adapter and then clip the adapter onto the DIN rail.
When installing the unit in an electrical cabinet, please observe that a protection must be used to prevent direct access to the electri-
cally conductive components.

CD 1 x 4 P8 for surface-mounting

The board is screwed into a IP 54 box and can be installed in false ceilings, partition walls or false floors in damp rooms.

Motor 1

Motor 2

Mains
230V 50Hz

       Live (L)
  Neutral (N)
Ground (PE)

 Jonction Box

Dry contacts control system :
Soliris IB
Chronis IB
Centralis IB
Outputs MCII

Local group control
motors 1 to 4

Local group control
motors 5 to 8

IB Bus line

to other CD 1x4 P
motor conrol units

Motor 3

SW1

ON

UP

AUTO ON/OFF

DOWN

IP

+

UP

AUTO ON/OFF

DOWN

IP

+

ON

Control
system

Mains

SW1

Motor 4

Motor 5

CD 1x4 P

CD 1x4 P

Motor 6

Motor 7

Motor 8

Connection wires:
max. 2.5 mm2 rigid wires or 1.5 mm2
stranded wires

PE (x6): Earth (all PEs are bridged)
L/N (x2) :Mains (both L and N are bridged)

M1 to M4: N/

/

▼ 

(x4)

Motors 1 to 4

Local 1: A /+/

/

/IP

on/off switch for all 4 motors (optional)
local switch (up/down/stop) for all 4 mo-
tors
local swirch for the intermediate  position
(“IP key”) for all 4 motors (optional)

Bus 20 V: 

/

/COM (x2)

IB Bus line (coming and going)

SW1:
Dipswitch for selecting roller 
shutters/awnings (ON) 
or Venetian blinds (OFF) for all 4 motors.

Summary of Contents for CD 1 x 4 P6

Page 1: ...only be carried out by a qualified electrician respect the local electrical standard Disconnect all the connection wires which are to be fitted Take the necessary safety measures to prevent uninten tional reconnection Proper functioning can only be guaranteed by expert installation and sufficient power supply 1 1 Assembly Wiring CD 1 x 4 P6 for the DIN rail When fitting the CD 1 x 4 P6 board on 35...

Page 2: ...ction open or bridge it Possibility to select two tilting functions European or US type European tilting mode Press briefly less than 0 8s the Venetian blind will be activated during the time of pressing tilting of the slats Press and hold more than 0 8s the Venetian blind will be activated during 3 minutes Up or Down control US tilting mode Press briefly less than 0 2s or continuous control longe...

Page 3: ...e UP key and the IP key on the local switch for approx 2 seconds until the shutter awning moves upwards Stop the shutter awning at the desired position which is to be the intermediate position from the lower end limit position by pressing Simultaneously the up and down keys or the IP key The intermediate position can be adjusted with the local switch Press and hold the IP key for at least 2 second...

Page 4: ...ded slat angle can be called up at any time after a local DOWN order i e blinds with closed slats by briefly pressing the IP key 5 3 Deleting the intermediate position The intermediate position and slat setting are deleted separately Deleting the intermediate position Move the 4 blinds to their programmed intermediate position Press the IP key for at least 10 seconds the intermediate position has ...

Reviews: