background image

Radio receiver for rolling garage door

Installation Manual

Power supply voltage  :

230Vac  50-60 Hz.

Fuse : 

250V 5A with timeout

Max motor power : 

230Vac 750W.

Protection rating  : 

IP 55.

Ambient operating T° :

-15°C to +55°C. 

Radio frequency  : 

433.42MHz

Accessory power supply  : 

24Vcc (direct).

Resistance values for resistive sensor

bar : 

From 5 to 14

K

Maximum current for accessories  : 

0.33A i.e. 8W max. 

(cells, keypads, loops, sensor bar, etc…) 

or 13W intermittent (orange light

10W + accessories 3W.)

Orange light : 

24V, 10W max or 230V 40W max

Area lighting  : 

230Vac, 500W.

Auxiliary output : 

Contact NO, 250Vac 500W.

Operating class :

1, the ground must be connected.

150 mm

150 mm

40 mm

=

Automatic mode

Pressing the remote control opens and closes automatically
after timeout

T1

(chapter 3.8).

During closing, pressing the remote control again or the
detection of an obstacle reopens the door.

=

Semi-automatic mode

Pressing the control triggers opening or closing. Pressing again
during opening has no effect. 
Pressing during closing reopens the door.

=

Sequence mode

Cyclic operation (up / stop / down / stop...).
Pressing during opening or closing stops without reversion.

=

Sequential mode + Timeout

Similar to the sequential mode, but with automatic closing aftert
timeout

T1

(chapter 3.8).

=

3-button mode

This mode is used to set a separate control
for opening, closing, and stopping the
door.

=

Forced mode with + & - keys on the

keyboard 

(default mode)

This mode is used to control the door using the “ 

” and 

“ 

” keys on the Axroll box in the endstop adjustment phase.

Press and hold “ 

” to open.

Press and hold “ 

” to close.

GB

3.1 Configuring the operating mode: parameter

 (plant value = 05)

The cross-section of the wires is given for information.

The 

AXROLL

receiver is used to control a rolling garage door fitted with

a 230V motor with built-in endstops using Keytis 2/4 RTS, Telis1/4 RTS,
and Inis RT transmitters. 
Different safety and signaling systems can be connected to the 

AXROLL

(sensor bar, photocells, flashlights, area lighting).

Ref.N1841017B V1     

SOMFY SAS, capital 20 000 000 Euros, RCS Bonneville 303 970 230

in this mode, the safety devices are deactivated

Mandatory installation of safety accessories

Mandatory installation of safety accessories

lighting or
signaling
chapter 3.7

Push-
button

sensor

bar

phot

oc

ells

MAINS

230V - 50Hz

2 x 0.75 mm

2

2 x 0.75 mm

2

4 x 0.75 mm

2

2 x 0.75 mm

2

2 x 0.75 mm

2

4 x 0.75 mm

2

3 x 1.5 mm

2

Certain operating modes impose connecting safety accessories (NF EN 12453). Non compliance with these rules can lead to a facility 
hazardous for its users. 

The Axroll has six operating modes:

Configuration

Use the “ 

+

“ or “ 

-

“ keys to change the value of the

parameter.
The last value is recorded automatically (the display is
fixed when pressing the keys).

1 sec.

Use the “ 

“ or “ 

“ keyrs to

browse the menu and display
the parameter required.

One second after releasing the key,
the screen indicates the parameter
value to change.
(display blinks)

The Axroll control box is fully and easily configured to achieve optimum operation matching the types of accessories connected, as

well as the operation mode required by the user.
The various parameters proposed are not mandatory, and browsing the menus imposes no particular sequence.

Powering on the product: the display indicates the value 

Check the motor’s rotation direction using the “ 

+

“ and “ 

-

“ keys. 

press and hold the “ 

+

“ key to open the door.

press and hold down the “ 

-

“ key to close the door.

If the operation is reversed, power off the product, and revert the motor’s wiring
(terminals 7 and 9).

Refer to the motor's installation manual to set the end stop system.

Ground

Phase

Neutral

Motor

Photocells

Ref: 9001000

Push-
button

Sensor

bar

Test

Supply

Contact

230V - 50Hz

Lighting configuration 

Ground

Phase

Neutral

lighting
500W max.

Orange light configuration 

orange lights.

switch off the mains before any intervention.

use flexible cables.

connect the ground cables.

after installation, no traction must be applied to the

terminal strips.

Apply the electric installation standards, as well as
the following points:

3

Wiring

1

Checking the motor’s rotation direction

2

Motor

Measure the motor operating time using permanent running (e.g. 20sec. for rising), then set the 

T0

parameter (motor operating time,

chapter 3.8) with a value slightly above the time observed (about +3 sec.).

This product complies with the standard “SHousehold and similar electrical appliances - Safety - Part
2-95: Particular requirements for drives for vertically moving garage doors for residential use” IEC
60335-2-95.
This contributes to implementing installations complying with the standard “safety in using motorised
doors” NF EN 12453. Axroll must be installed inside the garage with a motor equipped by a manual
override system.

To return to the menu, press the “ 

“ or “ 

“ keys to return to value C1 (or any other value indicating the

product’s operation: see § 4) or after a one-minute waiting time.

1

2

3

Pull the antenna wire

through the right-hand

wire grommet.

Hereby, SOMFY, declares that this product (AXROLL) is in compliance
with the essential requirements and other relevant provisions of
Directive 1999/5/EC.
A Declaration of Conformity is available at the web address
www.somfy.com Heading CE. 

Usable in EU,

CH

Reviews: