Radio receiver for rolling garage door
Installation Manual
Power supply voltage :
230Vac 50-60 Hz.
Fuse :
250V 5A with timeout
Max motor power :
230Vac 750W.
Protection rating :
IP 55.
Ambient operating T° :
-15°C to +55°C.
Radio frequency :
433.42MHz
Accessory power supply :
24Vcc (direct).
Resistance values for resistive sensor
bar :
From 5 to 14
K
Ω
Maximum current for accessories :
0.33A i.e. 8W max.
(cells, keypads, loops, sensor bar, etc…)
or 13W intermittent (orange light
10W + accessories 3W.)
Orange light :
24V, 10W max or 230V 40W max
Area lighting :
230Vac, 500W.
Auxiliary output :
Contact NO, 250Vac 500W.
Operating class :
1, the ground must be connected.
150 mm
150 mm
40 mm
=
:
Automatic mode
Pressing the remote control opens and closes automatically
after timeout
T1
(chapter 3.8).
During closing, pressing the remote control again or the
detection of an obstacle reopens the door.
=
:
Semi-automatic mode
Pressing the control triggers opening or closing. Pressing again
during opening has no effect.
Pressing during closing reopens the door.
=
:
Sequence mode
Cyclic operation (up / stop / down / stop...).
Pressing during opening or closing stops without reversion.
=
:
Sequential mode + Timeout
Similar to the sequential mode, but with automatic closing aftert
timeout
T1
(chapter 3.8).
=
:
3-button mode
This mode is used to set a separate control
for opening, closing, and stopping the
door.
=
:
Forced mode with + & - keys on the
keyboard
(default mode)
This mode is used to control the door using the “
+
” and
“
-
” keys on the Axroll box in the endstop adjustment phase.
Press and hold “
+
” to open.
Press and hold “
-
” to close.
GB
3.1 Configuring the operating mode: parameter
(plant value = 05)
The cross-section of the wires is given for information.
The
AXROLL
receiver is used to control a rolling garage door fitted with
a 230V motor with built-in endstops using Keytis 2/4 RTS, Telis1/4 RTS,
and Inis RT transmitters.
Different safety and signaling systems can be connected to the
AXROLL
(sensor bar, photocells, flashlights, area lighting).
Ref.N1841017B V1
SOMFY SAS, capital 20 000 000 Euros, RCS Bonneville 303 970 230
in this mode, the safety devices are deactivated
Mandatory installation of safety accessories
Mandatory installation of safety accessories
lighting or
signaling
chapter 3.7
Push-
button
sensor
bar
phot
oc
ells
MAINS
230V - 50Hz
2 x 0.75 mm
2
2 x 0.75 mm
2
4 x 0.75 mm
2
2 x 0.75 mm
2
2 x 0.75 mm
2
4 x 0.75 mm
2
3 x 1.5 mm
2
Certain operating modes impose connecting safety accessories (NF EN 12453). Non compliance with these rules can lead to a facility
hazardous for its users.
The Axroll has six operating modes:
Configuration
Use the “
+
“ or “
-
“ keys to change the value of the
parameter.
The last value is recorded automatically (the display is
fixed when pressing the keys).
1 sec.
Use the “
“ or “
“ keyrs to
browse the menu and display
the parameter required.
One second after releasing the key,
the screen indicates the parameter
value to change.
(display blinks)
The Axroll control box is fully and easily configured to achieve optimum operation matching the types of accessories connected, as
well as the operation mode required by the user.
The various parameters proposed are not mandatory, and browsing the menus imposes no particular sequence.
Powering on the product: the display indicates the value
Check the motor’s rotation direction using the “
+
“ and “
-
“ keys.
press and hold the “
+
“ key to open the door.
press and hold down the “
-
“ key to close the door.
If the operation is reversed, power off the product, and revert the motor’s wiring
(terminals 7 and 9).
Refer to the motor's installation manual to set the end stop system.
Ground
Phase
Neutral
Motor
Photocells
Ref: 9001000
Push-
button
Sensor
bar
Test
Supply
Contact
230V - 50Hz
Lighting configuration
Ground
Phase
Neutral
lighting
500W max.
Orange light configuration
orange lights.
switch off the mains before any intervention.
use flexible cables.
connect the ground cables.
after installation, no traction must be applied to the
terminal strips.
Apply the electric installation standards, as well as
the following points:
3
Wiring
1
Checking the motor’s rotation direction
2
Motor
Measure the motor operating time using permanent running (e.g. 20sec. for rising), then set the
T0
parameter (motor operating time,
chapter 3.8) with a value slightly above the time observed (about +3 sec.).
This product complies with the standard “SHousehold and similar electrical appliances - Safety - Part
2-95: Particular requirements for drives for vertically moving garage doors for residential use” IEC
60335-2-95.
This contributes to implementing installations complying with the standard “safety in using motorised
doors” NF EN 12453. Axroll must be installed inside the garage with a motor equipped by a manual
override system.
To return to the menu, press the “
“ or “
“ keys to return to value C1 (or any other value indicating the
product’s operation: see § 4) or after a one-minute waiting time.
1
2
3
Pull the antenna wire
through the right-hand
wire grommet.
Hereby, SOMFY, declares that this product (AXROLL) is in compliance
with the essential requirements and other relevant provisions of
Directive 1999/5/EC.
A Declaration of Conformity is available at the web address
www.somfy.com Heading CE.
Usable in EU,
CH