background image

 

Motorisation of Window Coverings 

using Somfy Motors

 

 

Altus 50 Motor (integrated Radio receiver)  

Suitable for roller and roman blinds plus awnings 

Power Cable 

Blue = Neutral 

Brown = Active 

Green/Yellow = Earth 

 

Nominal Supply Voltage = 220/240V 

Current consumption at nominal torque = 270 watts (maximum) 

Running Current = 1.2 amps (maximum) 

Cable length = 3m 

Cable size = 3 x 0.75 

 

 

Concept 25 Motors 

Suitable for slimline venetians, pleated and cellular blinds 

 

Nominal Supply Voltage = 24V DC 

Current consumption = 600 mA (maximum) 

Cable length = 2.5m 

Cable size = 2 x 0.25 

Summary of Contents for ALTUS 50

Page 1: ...Motorisation of Window Coverings using Somfy Motors...

Page 2: ...ncipal The motor drives the wheel The wheel drives the roller tube The roller tube drives the crown The crown drives the limit switch within the motor ATTENTION Somfy Motors are not waterproof Do not...

Page 3: ...Cable length 2 5m Cable size 3 x 0 75 Important LS40 motors must never be wired in parallel Damage caused by parallel wiring will not be covered under warranty LT50 Motor Suitable for roller blinds an...

Page 4: ...mand Cable length 2m Cable size Flat 4 core multistrand date cable Nominal Supply Voltage 220 240V Current consumption at nominal torque 270 watts maximum Running Current 1 2 amps maximum Altus 40 Mot...

Page 5: ...rown Active Green Yellow Earth Nominal Supply Voltage 220 240V Current consumption at nominal torque 270 watts maximum Running Current 1 2 amps maximum Cable length 3m Cable size 3 x 0 75 Concept 25 M...

Page 6: ...utdoor installations Do Not use other switches and controls other than those recommended by Somfy When using a Somfy control box plug in type make sure the power supply is switched off before plugging...

Page 7: ...e motors A will stop at its pre set limit before the other B Current from motor B will then flow back through to motor A through capacitor C2 and micro switches M3 and M1 There will be constant feedba...

Page 8: ...des interlocking between up and down commands Dry contact impulse switching impulse contact closure of 1 second minimum Contact between common and up or common and down to activate motor Simultaneous...

Page 9: ...ween a common up and down to create a stop ML9000 Power supply and master controller Can control up to 16 individual motor controllers Dimensions 85 h x 70 w x 62 d 4 DIN rail slots ML8000 Individual...

Page 10: ...es interlocking between up and down commands Dry contact impulse switching impulse contact closure of 1 second minimum Contact between common and up or common and down to activate motor Simultaneous c...

Page 11: ...Allows for connection between RJ11 connector and standard data cable Dry contact impulse switching impulse contact closure of 1 second minimum Contact between common and up or common and down to acti...

Page 12: ...nimum Contact between common and up or common and down to activate motor Simultaneous contact between a common up and down to create a stop One transmitter for each command required Transmission range...

Page 13: ...ween a common up and down to create a stop RS232 connection o Bits per Second 1200 o Data bits 8 o Parity None o Stop Bits 1 o Flow Control Hardware o Commands U1 Up Command Channel 1 S1 Stop Command...

Page 14: ...Motorisation of Window Coverings using Somfy Motors Option 2 cont Busline Transmitter Five channel...

Page 15: ...oncept 25 IRS 300 Supply voltage 24V DC Dry contact impulse switching impulse contact closure of 5 seconds minimum Contact between common and up or common and down to activate motor Simultaneous conta...

Reviews: