2.5. SETTING THE TIME OF FUNCTIONING
The operating duration of the heating lamp before automatic shut-down can be configured.
The default setting is 6 hours.
To change this setting:
1) Briefly press the
my
and
Down
buttons simultaneously on the
io local control point.
2) Just afterwards, press the
my
and
Down
buttons simultaneously
and keep depressed until the heating lamp turns on then turns
off.
• Briefly press the
Down
button to set the duration to 3 hours.
• Briefly press the
my
button to set the duration to 6 hours.
• Briefly press the
Up
button to set the duration to 12 hours.
The heating lamp turns on then turns off.
3) Press the
my
button until the heating lamp turns on then turns off.
The new setting is programmed.
2.6. TIPS AND ADVICE ON INSTALLATION
2.6.1. Questions on the io 2kW Heating Slim Receiver?
Observations
Possible causes
Solutions
Pressing a button on the
control point has no effect on
the heating lamp
The control point has not been
programmed in the io 2kW
Heating Slim Receiver.
Follow the commissioning
procedure (see
2.3.
)
The batteries in the control
point are low.
Replace the batteries, using the
same battery model.
The control point used is not
compatible with the io 2kW
Heating Slim Receiver.
Ensure the two products are
compatible.
The power supply is faulty.
Check the power supply.
2.6.2. Replacing a lost or broken io control point
Attention
• This reset is carried out if all the io control points have been lost or broken.
• Only switch the power off twice to the io 2kW Heating Slim Receiver to be reset!
0.5 s
< 2 s
= 6 h