Specifications
The Mount is specifically designed to be placed on marine vessels and floating platforms. A usage in other
vehicles needs to be checked and cannot be verified in general because the performance may vary.
Angular Stabilization Ranges
Pitch - at 0° Roll
Roll - at 0° Pitch
≤ ± 20.0°
≤ ± 20.0°
Yaw (Drift)
no drift correction
Residual Deviation
1
≤ 0.4° rms
Payload
2
100 kg / 70 kg / 55 kg
Continuous Torque
3
125 Nm
Dynamic Peak Torque
4
250 Nm
Mass
33 kg
Dimensions (regular leveling positions):
Height
Diameter
290 mm
Ø 486 mm
IP Class
IP 67
Operating Temperature
-30 °C to +55 °C
Storage Temperature
-55 °C to +85 °C
Communication Interfaces
Ethernet / RS422 / RS232
Operational Voltage
28 VDC (
24 … 30 VDC)
Average Power Consumption
5
at Operational Voltage
90 W
Peak Power Consumption
450 W
Applied Standards
IACS E10, DNV GL, 2006/42/EC Machinery
Preliminary data, subject to change
1
Vehicle motion ≤ ±
18° / 15°/s / 40°/s² / small periodical
lateral accelerations (≤ 0.5 g) acceptable, constant lateral accelerations for
more than 1 minute reduce the performance of the Mount (can be compensated by external GPS input)
2
Possible payload weight depends on lateral acceleration and CoG of payload / shown data is based on 0.9 g lateral acceleration and a
CoG payload offset to the Mount surface of: 250 mm / 400 mm / 500 mm; further information is shown in section 4.1.2
3
See chapter 4.1.3 for continuous torque estimation
4
Maximum duration 90 s at 55 °C surrounding temperature / longer if temperature inside the unit is < 55 °C
5
Horizontal payload CoG offsets are not considered; without wind force and other possible external forces