21
/
53
7
Screws-M5*8
1
8
Screws-M4*6
6
9
Wrench 3#
1
10
Expansion bolts-M8*100
4
11
Module mounting bracket
2
12
Wall mounting bracket
2
13
CAN1 communication line
1
14
CAN2 communication lie
1
15
User manual
1
16
RJ45 terminal
2
17
Current sensor
1
3.4.2 Basic installation requirement
The energy storage integrated machine cabinet is IP20 and suitable for
installation in dry, dust-free environments. According to EMC standards, the
energy storage integrated machine cabinet is designed to meet the installation
requirements in a home environment. Select the installation site according to
the following requirements:
●
The installation site should be well ventilated, free from rain and direct sunlight;
●
The installation floor should be dry and flat. It is strictly forbidden to have water on
the ground; ensure that the ground level is not shaken and can fully carry the
weight of the energy storage integrated machine cabinet.
●
The temperature in the installation environment should range from -10 °C to
40 °C; the relative temperature should range from 4 to 100 %.
●
Reserve enough installation spacing between the front, rear, left and right, top
and wall of the energy storage integrated machine cabinet to ensure good
ventilation, heat dissipation, installation and maintenance, and safe escape.
●
There are no combustible gas and flammable materials nearby.
●
The installation environment should be clean.
Summary of Contents for S12 EU-A36
Page 1: ...1 53 User Manual Home Energy Storage System Soluna S12 EU Oct 2020 Revision A 1 ...
Page 18: ...18 53 Figure 2 5 Appearance Number Name Remark Door lock of system Door key ...
Page 30: ...30 53 Step7 Electrical connection 1 Soluna S12EU A36 2 Soluna S12EU A50 ...
Page 31: ...31 53 3 Soluna S12EU A80 ...
Page 36: ...36 53 Figure 4 5 PV information Figure 4 6 Load information Figure 4 7 Grid information ...