32 UM0005_ASW 8-20K-LT-G2_EN_V03_1121
Procedure:
1. Make sure DC power is cut off.
2. Unscrew the swivel nut.
3. To release the DC connector, insert a flat-blade screwdriver
(blade width: 3.5 mm) into the side catch mechanism and
lever open.
4. Carefully pull the DC connector apart.
5. Release the clamping bracket. To do so, insert a flat-blade
screwdriver (blade width: 3.5 mm) into the clamping bracket
and lever it open.
6. Remove the cable.