background image

1

2

3

4

6

5

7

Technical data

Column Stage 

Max. Weight Capacity

 

Height Range 

Width Range

27.1"-46.5"(Without table top) 

220lbs

43.3"-74.8"

Component list

6

1

3

1

4

1

7

1

1

2

2

2

5

2

No.

Part

Qty No.

Part

Qty

No.

Part

Qty No.

Part

Qty

No.

Part

Qty No.

Part

Qty

No.

Part

Qty

Feet

Lifting Column

Supporting Beam

(Control Box included)

Cable Management Tray

Side Bracket

Hand Switch 

(Option)

Power Plug

A

C
D

4

B

E

4

F

16

12

8

1

Accessory list

fer 

Attention: The drawings below are for guidance only and they may dif

slightly from the product and fittings received. Please contact our customer 

service department should you have any queries.

No. 

Image 

Spec 

Qty 

Allen Key

0.16"x0.16"

St4.2

M6

M6

M6

M6

SKU: SD-ET147

SOLOS V2 Standing Desk User Manual

Summary of Contents for V2 Standing Desk SD-ET147

Page 1: ... Feet Lifting Column Supporting Beam Control Box included Cable ManagementTray Side Bracket Hand Switch Option Power Plug A C D 4 B E 4 F 16 12 8 1 Accessory list fer Attention The drawings below are for guidance only and they may dif slightly from the product and fittings received Please contact our customer service department should you have any queries No Image Spec Qty Allen Key 0 16 x0 16 St4...

Page 2: ...the Control Panel 7 Port for hand switch Power port Port for cable connected to the lifting column B 4 3 B x4 STEP 6 Install the Cable ManagementTray Method 1 3 Tighten Firstly with rotate the screws B incompletely into the supporting beam 4 Allen Key F which means do not tighten them Next slide one side of the cable management tray 3 into the screws B then the other side Finally tighten the screw...

Page 3: ...4 D F 2 D x8 STEP 2 Install the Lifting Columns Insert the lifting columns 2 into the ends of the supporting beam 4 Fix the lifting columns using screws D with theAllen Key F Install the Feet C F 1 2 C x8 STEP 3 Place the feet 1 on the bottom of the lifting column 2 Fix the feet using screws C withAllen Key F F 0 16 x0 16 F 0 16 x0 16 A x4 F 0 16 x0 16 ...

Page 4: ...pressing up arrow down arrow after connected with a power supply Downward Sliding Frequently Reposition Overwork Not enough up down height Method Fault Phenomenon ion Attent 1 Power supply AC100V 240V 50 60Hz 2 Service Environment 0 40 3 Unplug the power plug before cleaning wipe the dust on surface with slight wet dishcloth when cleaning be careful not to let the drops into the internal parts not...

Reviews: