Once you are in Open-
loop mode, the “P/F” input acts as Power input and it has direct
relation with the value of the voltage at this pin ( the higher the voltage at P/F, the
higher the power injected into motor), but in closed loop mode “P/F” acts as current
limit and it has reverse relation with the voltage on this pin ( the higher the voltage the
lower will be the allowed current into the motor), so if this is the first time you are
going to identify your motor parameters, and going to closed-loop mode, make sure the
“P/F” input has no voltage on it ( you can leave it open or apply 0v or 0% duty cyc
le to
it), and keeping the system in closed-loop mode, you can leave the switch on closed-
loop (C.L) forever even after turning the whole system OFF and then later ON. ( as long
as the motor and wiring are the same).
The identified Motor parameters will remain in long term non-volatile memory of SOLO
(NVM memory), and after power recycling they will be remembered, so no need to re-
identify the motor every time you turn the system ON.