4.5.2
Troubleshooting ignition systems
•
No spark on one Ignition circuit
o
Wire defect on one wire from the pick-ups or at a wire to the ignition
coil.
o
Wire from one pick-up to the ignition coil has connection to ground.
o
The shut-off-wire for one circuit has connection to ground
o
The relating ignition coil has a defect. This can be checked if the wires
to coil 1 are exchanged with the ones to coil 2. If the defect is moving
to the other circuit the coil has to be replaced.
o
If the defect is not moving then a coil in the stator or one of the pick-
ups have to be replaced.
•
No spark on both ignition circuits
o
Wire defect at the wires to the ignition coils.
o
Wires from the pick-ups or from the generator coils to the ignition coils
have connection to ground.
o
Shut-Off-wires have connection to ground.
•
No charging current
o
Wire defect at the wires from the coils to the stabilizer.
o
Wires to the stabilizer have connection to ground.
o
Plugs at the stabilizer have a defect.
o
Are all previous defects not present the stabilizer has to be replaced.