Getting Started

1. Download the software from: 

www.solinst.com/downloads 

and install Levelogger Software on your PC.

2. Install the Wellhead batteries. The Wellhead uses 4 user-

replaceable 1.5V AA lithium batteries. 

3. Connect the Wellhead and logger to the Vented Cable: 

Support 

Hanger 

Bracket

- 2 -

Note:

Note:

 See page 6 for instructions to install the Support Hanger  

 See page 6 for instructions to install the Support Hanger  

 

Bracket, as shown at right.

 

Bracket, as shown at right.

Note: 

Note: 

For information on using your AquaVent 5 logger with  

For information on using your AquaVent 5 logger with  

 

MODBUS or SDI-12 protocols, see separate User Guides.

 

MODBUS or SDI-12 protocols, see separate User Guides.

Battery  

Compartment

SP  

Wellhead

Vented 

Cable

AquaVent 5 

Logger

10-Pin (SP) 

Connection

Line up the socket and the pin. Gently push the Wellhead and Vented 

Cable together and twist slightly until you feel/hear a small click when 

the properly aligned connection is made. 

Only tighten the stainless steel coupling

 while holding the Vented Cable 

and Wellhead still. Tighten the coupling until it seats. Do not twist the 

Vented Cable or Wellhead. 
Follow the same procedure when connecting the logger to the Vented 

Cable. 

Well Cap 

Base

Vented Cable  

alignment socket

Wellhead and logger  

alignment pin

Only Turn Coupling

Hold Vented 

Cable Still

Hold 

Wellhead 

Still

Summary of Contents for AquaVent 5 3500

Page 1: ...High Quality Groundwater and Surface Water Monitoring Instrumentation Quick Start Guide 3500 AquaVent 5 Please read this document carefully before using the AquaVent 5 More Info Instructions Get Quote...

Page 2: ...t 5 logger with MODBUS or SDI 12 protocols see separate User Guides MODBUS or SDI 12 protocols see separate User Guides Battery Compartment SP Wellhead Vented Cable AquaVent 5 Logger 10 Pin SP Connect...

Page 3: ...e will provide you with a short explanation of that feature in the software will provide you with a short explanation of that feature e g Com Port Datalogger Zero Slate Mode Time Synchronization etc e...

Page 4: ...surement as data is being recorded by the connected logger A view rate is set independently of the logging period of the AquaVent 5 and does not interfere with internal logging taking place To take a...

Page 5: ...level measurement using a water level meter This reading should correspond in data and time with an actual AquaVent 5 recording Use this as a reference datum in the Manual Data Adjustment option in th...

Page 6: ...ed to be conveniently installed on a 2 well casing 4 using an adaptor However other installations are acceptable if proper precautions and recommendations are followed Leave at least 2 50 mm of slack...

Page 7: ...ue red USB connection has been dropped Flashing yellow The Wellhead is communicating with the PC Software Maintenance As with any monitoring project you should select the proper equipment and determin...

Page 8: ...lder 2 Check the Vented Cable connections to the AquaVent 5 logger and Wellhead Ensure they are lined up correctly and there is no dirt or debris in the connection 3 Make sure you are using the correc...

Reviews: