Solight DY10GSM Quick Start Manual Download Page 2

 

 

10 Temperature alarm: 

The temperature sensor must be connected to the socket for this function. The temperature range can be set for every single socket 
individually. If the ambient temperature is outside the specified limit, the DY10GSM will send an SMS to the master user's phone number.  
 
The master user will send SMS command for:  

 

Alarm activation for DY10GSM socket when the temperature is exceeded: 

#21#0#1#                            

 

 

Alarm activation for DY10S socket when the temperature is exceeded:

 

#

68#name#1#

            

 

Setting the DY10GSM temperature alarm range:

 

#22#0#MinTemp#MaxTemp#

             

 

Setting the DY10S temperature alarm range:

  

#69#name#MinTemp#MaxTemp# 

 

MinTemp

 and 

MaxTemp

: Values can be set in the range from -10 to 50°C. 

 

 

Deactivating the temperature alarm for DY10GSM

#21#0#0# 

 

Deactivating the temperature alarm for DY10GSM: 

 

#68#name#0# 

 

11 SMS notification at a change of power outlet status: 

By default, the DY10GSM sends SMS notification to the master phone number and other numbers in case of a change of the power outlet 
status. The master user can turn this function on or off.  
 
The master user will send SMS command for: 

 

Activation of SMS notification in case of a change of the power outlet status (active in default setting):

 

#03#1#

       

 

Deactivation of SMS notification in case of a change of the power outlet status.

 

#03#0# 

12 SMS notification in case of a change of power status: 

By default, the DY10GSM sends SMS notification when power is lost and restored. This applies only to the DY10GSM socket; the DY10S socket 
is not capable of this function. The master user can turn this SMS notification on or off. 
The master user will send SMS command for: 

 

SMS notification in case of a change of the power status (active in default setting):

 

#05#1# 

 

Deactivation of SMS notification in case of a change of the power status.

 

#05#0# 

 
 

SMS notification to user 

The DY10GSM will send an SMS notification when the power is lost/restored, temperature alarm triggered or in case of another notification. 
By default, it sends messages to the master user and other users. The master user can change the settings of sending notifications to other 
users' numbers. 
 
The master user sends SMS command for: 

 

Activating SMS notifications for other users

:

 #

16#1#

 

 

Deactivating SMS notifications for other users

#16#0#

 

 

13 Checking the socket status: 

The master user or another user will send SMS command for: 

 

Checking the DY10GSM status:

  

#07#

 

 

Checking the DY10S status:

 

#70#

 

Upon receipt of the SMS command, an SMS message with socket status information will be sent to the user: 
 

GSM-Socket: ON    Temp: 23C 

“Slave1”: OFF      Temp: 30C   T 

“Slave2”: ON       Temp: 23C   C 

“Slave2”: ON       Temp: 25C   D 

 

Delayed control socket is marked with “D” symbol. Socket with temperature control feature is marked with "T” symbol. Socket with calendar 

control feature activated is marked with “C” symbol. 

 

 

Checking DY10GSM delayed control parameters:

 

#34#

 

 

Checking DY10S delayed control parameters:

 

#63#name#

 

 

 

Checking DY10GSM calendar control parameters:

 

#33#

 

 

Checking DY10S calendar control parameters:

 

#64#name

  

 

 

Checking DY10GSM temperature control parameters:

 #32#

 

 

Checking DY10S temperature control parameters:

 

#66#name

 

 

 

Checking DY10GSM parameters for temperature alarm:

 

#35#0#

 

 

Checking DY10S parameters for temperature alarm:

 

#68#name#

 

 

14 SMS notification on weak GSM signal: 

The DY10GSM socket can send an SMS message when the GSM signal is weak. The master user can turn this function on/off.  

 

The master user will send SMS command for: 

 

Checking GSM signal level:

 #27# 

 

Activation of SMS notification when the signal is weak:

 

#27#1#

 

 

Deactivation of SMS notification when the signal is weak: 

#27#0#

 

 

SMS response 

Weak GSM signal strength alert function ON/OFF 

 

Weak GSM signal alert will send an SMS notification: 

Weak GSM signal alert, the CSQ is ** 

 

15 Socket re-set: 

This function will re-set all socket settings (time, temperature, ranges, etc.) and clear all user numbers.  

If the socket does not work as it should, you can reset it to default settings to ensure possible new setting and correct function. DY10S must be 

reset before pairing with the main unit (unless it being paired for the first time). 

 

DY10GSM

 reset to default settings: 

Method 1: Press "M" button on the socket for 10s.  

Method 2: The master user will send SMS command for: 

 

DY10GSM socket re-set:

 

#08#Password#

 

Default password setting - 1234  

 

DY10S

 reset to default settings: 

Approach: Press "M" button on the socket for 10s. 

 

 

16 Password change: 

The master user will send SMS command for: 

Password change:

 

#04#OldPassword#NewPassword# 

 

Main technical parameters: 

Supply voltage 

110~230V/50HZ, 

Output parameters 

110 - 230V/50HZ, 230V/30A(30s) 

Max. current 

16A 

Operating temperature 

-10

+50

 

Storage temperature 

-20

+60

 

Relative humidity 

10-90% 

Communication protocol 

GSM PHASE 2/2+  

(including data operation) 

Data interface 

GSM SIM 1.8V/3.0V socket 

Frequency and coding 

433MHz FSK 

Additional socket distance 

Up to 30m 

Measurement sensor range: 

-10

~50

 

GSM bands 

850/900/1800/1900MHz 

 

SMS commands: 

Category 

Function 

Command 

Defining a user 

New user registration 

#00# 

Change of master user’s phone 

number: 

#14#NewMasterNumber# 

Adding a new user’s number 

#06#Family# 

Checking other users’ numbers 

#06# 

Deleting another user’s number 

#15#Family# 

Deleting all other user numbers 

#15# 

Pairing the 

DY10S socket 

Pairing the additional socket 

#60#name# 

Disconnecting the additional socket 

#70#name# 

Power outlet 

changes 

Switching DY10GSM socket on 

#01#0# 

Switching DY10S socket on 

#61#name# 

Switching DY10GSM socket off 

#02#0# 

Switching DY10S socket off 

#62#name# 

Delayed control 

Delayed activation of DX10GSM after 

pre-set time in minutes 

#12#0#Minutes#1# 

 

Category 

Function 

Command 

Delayed activation of DY10S after pre-

set time in minutes 

#63#name#Minutes#1# 

Delayed activation of DY10GSM after 

pre-set time in minutes 

#12#0#Minutes#0# 

Delayed control 

Delayed activation of DY10S after pre-

set time in minutes 

#63#name#Minutes#0# 

Deactivate delayed DY10GSM control 

#11#0# 

Deactivate delayed DY10S control 

#63#name#0# 

Operation by 

calendar 

Activation of DY10GSM operation by 

calendar 

#19#0#1# 

Activation of DY10S operation by 

calendar 

#64#name#1# 

Setting calendar parameters for 

DY10GSM 

#20#0#WorkDay#StartTime#EndTime# 

Setting calendar parameters for DY10S 

#65#name#WorkDay#StartTime#EndTime# 

Deactivating calendar control for 

DY10GSM 

#19#0#0# 

Deactivating calendar control for 

DY10S 

#64#name#0# 

Control by 

ambient 

temperature 

Activation of control by ambient 

temperature for DY10GSM 

#23#0#1# 

Activation of control by ambient 

temperature for DY10S 

#66#name#1# 

Setting temperature parameters for 

DY10GSM 

#24#0#mode#MinTemp#MaxTemp# 

Setting temperature parameters for 

DY10S 

#67#name#mode#MinTemp#MaxTemp# 

Deactivation of control by ambient 

temperature for DY10GSM 

#23#0#0# 

Deactivation of control by ambient 

temperature for DY10S 

#66#name#0# 

Temperature 

monitoring 

Activation of temperature monitoring 

for DY10GSM 

#21#0#1# 

Activation of temperature monitoring 

for DY10S 

#68#name#1# 

Setting temperature range for 

DY10GSM 

#22#0#MinTemp#MaxTemp# 

Setting temperature range for DY10S 

#69#name#MinTemp#MaxTemp# 

Deactivation of temperature 

monitoring for DY10GSM 

#21#0#0# 

Deactivation of temperature 

monitoring for DY10S 

#68#name#0# 

 

SMS notification on change of the 

power outlet status 

#03#1# 

Deactivation of SMS notification on 

change of the power outlet status 

#03#0# 

SMS notification in case of a change of 

power status 

#05#1# 

Deactivation of SMS notification in case 

of a change of power status 

#05#0# 

SMS 

notification 

SMS notification to other users 

#16#1# 

Deactivation of SMS notification to 

other users 

#16#0# 

Status check 

Checking the DY10GSM status 

#07# 

Checking the DY10S status 

#70# 

Checking the pre-set values of delayed 

control for DY10GSM 

#34# 

Checking the pre-set values of delayed 

control for DY10S 

#63#name# 

Checking the pre-set values of calendar 

control for DY10GSM 

#33# 

Checking the pre-set values of calendar 

control for DY10S 

#64#name# 

 

Category 

Function 

Command 

Checking the pre-set values of ambient 

temperature control for DY10GSM 

#32# 

Checking the pre-set values of ambient 

temperature control for DY10S 

#66#name# 

Checking the pre-set values for 

temperature alarm DY10GSM 

#35#0# 

Checking the pre-set values for 

temperature alarm DY10S 

#68#name#

 

Checking GSM signal quality 

#27# 

Turn on weak signal alert 

#27#1# 

Turn off weak signal alert 

#27#0# 

Password 
change 

Password change 

#04#OldPassword#NewPassword#

 

Socket re-set 

Re-set DY10GSM to default settings 

#08#Password# 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The product is CE (Declaration of Conformity) certified, in accordance with current regulations. On request, at the producer: [email protected], or 
for download at shop.solight.cz. Producer: Solight Holding, s.r.o., Na Brně 1972, Hradec Králové 500 06, Czech Republic 

Reviews: