ENABLE:
Enables the streaming send for
Icecast/
shoutcast
.
DESTINATION ADDRESS:
Target IP address for the
outcoming stream.
PORT:
Transmission TCP port.
CODEC:
Audio format for the RPT stream. It can
be PCM or MP3.
QUALITY:
MP3 for MP3 or sample rate for PCM.
4.7.5 DOWN-STREAM
(RX)
Settings for the incoming streaming. Supports RTP
streams or public HTTP streams.
4.7.6 STREAMING NETWORK
Network settings for the
UX24 streaming module
.
At the present version this settings are fixed and de-
pends on the settings of the LAN (DHCP).
4.8 GPIO
UX24 have
4 GPI
(
general purpose inputs
) and
8
GPO
(
general purpose outputs
).
GPIO connections and common applications was
detailed above in section
2.9 – GPIO
.
The behavior for each GPIO sets in the following
screen:
Each file correspond to one GPI or GPO.
For each GPI/O the user can assign an action from
the drop-down menu ACTION.
Each GPIO can be associated to one channel, which
is selected from the menu CHANNEL.
The actions available for the GPI are:
UNASSIGNED
CHANNEL ON/OFF
MASTER MIC A
MASTER MIC B
The actions available for the
GPO
are:
UNASSIGNED
CHANNEL ON/OFF
TALLY A
TALLY B
TELCO RING
Examples:
The following settings:
GPI 1 | CHANNEL ON/OFF | CHANNEL 1
...will cause that
Channel 1 turn on/off
according to the signal
present at the input GPI 1.
The following:
GPO 1 | CHANNEL ON/OFF | CHANNEL 6
...will cause that output GPO 1 changes its status when the Chan-
nel 6 is turned on or off.
4.9 SETTINGS: USERS
UX24 has three user levels: ADMIN, EXPERT, BASIC.
The ADMIN and EXPERT users are password pro-
tected, which are defined on this screen. Only the
ADMIN user can change passwords.
Default passwords
are user names, in lower case
(admin and expert).
DEFAULT USER
Defines the user that loads when the console starts.
By default ADMIN.
When start up, the system never will ask by pass-
word, no matter which is the default starting user.
To restrict access to advanced features, change the
default boot user (ADMIN) to BASIC or EXPERT, de-
pending on the level of restriction needed. Thus, if
the console starts with a BASIC profile, passwords
for EXPERT or ADMIN must be known in order to ac-
cess restricted features. For example: If the console
starts with an EXPERT profile, only the features that
require ADMINISTRATOR level will be blocked.
4.10 AoIP
Settings options for
DANTE
module
, if available.
Page 26
Solidyne UNIDEX UX24