Appendix C. Solida Multi Remote Monitoring
Solida Multi is a remote monitoring software tool that allows for monitoring multiple appliances
remotely over the Internet.
C.1 Setting Up The Solida Multi Sever
Before the Solida Multi software can be installed the user must decide if the server should be
hosted in the cloud or be installed as a physical server. In both cases it is required that the server
is assigned a fixed IP address. This IP address is then passed to the security appliance during
configuration. The server needs to run the Linux operating system. If the server uses Windows
then Solida Multi must be installed as a virtual instance under Windows.
C.2 Configuring The Appliance for Solida Multi
It is straightforward to configure the appliance so that it starts communication with the remote
computer hosting Solida Multi. The IP address of the server hosting Solida Multi must be provided
together with a user name and password for a remote login connection.
C.3 Required Network Ports.
The security appliance will communicate with Solida Multi over port 22 (ssh). If port 22 is blocked
by a firewall then the appliance require port 443 (https) to be opened for this communication.
Port 53 must also be open for DNS lookups.
C.4 Communication
Once the security appliance has been set up to communicate with a Solida Multi server it will start
sharing security data.