background image

Confidential & Proprietary 

11/20 

Specifications of eROUa 

Item 

Spec. 

Remark 

eROU 

The rated mean output Power 

per band 

600 

700LTE_FN 

8085 

+19dBm

1900P 

AWS13 

2300WCS 

2500_100TDD 

+23dBm

3500CBRS 

N/A 

The nominal downlink 

bandwidth 

600 

35MHz 

700LTE_FN 

39MHz 

8085 

32MHz 

1900P 

65MHz 

AWS13 

70MHz 

2300WCS 

10MHz 

2500_100TDD 

194MHz 

3500CBRS 

N/A 

The nominal uplink bandwidth 

600 

35MHz 

700LTE_FN 

700FN B1 : 17MHz 

700FN B2 : 21MHz 

8085 

32MHz 

1900P 

65MHz 

AWS13 

70MHz 

2300WCS 

10MHz 

2500_100TDD 

194MHz 

3500CBRS 

N/A 

The nominal passband gain 

Downlink 

600 

61dB 

700LTE_FN 

63dB 

8085 

58dB 

1900P 

67dB 

AWS13 

67dB 

2300WCS 

69dB 

Summary of Contents for Alliance eROU

Page 1: ... Proprietary 1 20 Alliance eROU eROUa User Manual Document Reference Version V1 2 Document Status Release 4 Issue Date Jan 25 2022 Author Hyo Seok Oh Department R D Division Team 2 Authorizing Manager hyun suk Chae ...

Page 2: ...bers must be available to authorize technical support and or to establish a return authorization for defective units The serial numbers are located on the back of the unit as well as on the box in which they were delivered Additional support information may be obtained by accessing the SOLiD Tehcnology Inc website at www solid co kr or send email at sjkim solid co kr This manual is produced by Glo...

Page 3: ... edge Remote Optic Unit 9 2 1 1 Specifications of eROU 11 2 1 2 Port on eROU 12 2 1 2 1 Functions 12 2 2 AC DC Adaptor information 14 Section3 System Installation 15 3 1 eROU Installation 15 3 1 1 eROU Enclosure installation 15 3 1 2 eROU External Antenna Mount Installation 18 3 1 3 Installation Cable Gland 19 3 1 4 Power cabling 20 ...

Page 4: ...Confidential Proprietary 4 20 Section1 Safety Certification Notice ...

Page 5: ...system is operating Do not operate this unit on or close to flammable materials as the unit may reach high temperatures due to power dissipation Do not use any solvents chemicals or cleaning solutions containing alcohol ammonia or abrasives on the DAS equipment Alcohol may be used to clean fiber optic cabling ends and connectors To prevent electrical shock switch the main power supply off prior to...

Page 6: ...use with a wireless connection via server antenna to the base station Access can only be gained by SERVICE PERSONS or by USERS who have been instructed about the reasons for the restrictions applied to the location and about any precautions that shall be taken and Access is through the use of a TOOL or lock and key or other means of security and is on trolled by the authority responsible for the l...

Page 7: ...e limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely t...

Page 8: ... choisir le type d antenne et son gain de sorte que la puissance isotroperayonnée quivalente p i r e ne dépassepas l intensité nécessaire à l établissement d une communication satisfaisante Max gain 17 dBi RF Radiation Exposure This equipment complies with RF radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with a minimum distance ...

Page 9: ...ultiplexer When receiving RX signals through the antenna port this unit filters out of band signals in a corresponding Multiplexer and sends the results to OPTIC to make electronic optical conversion of them After converted the signals are sent to a upper device of eHUB For this application eROUa receives RF signals from eROU The received RF signals are radiated through the AMP and multiplexer to ...

Page 10: ...Confidential Proprietary 10 20 Integrated Antenna External Antenna Figure 2 eROU outer Look Only External Antenna Figure 3 eROUa outer Look ...

Page 11: ...ominal downlink bandwidth 600 35MHz 700LTE_FN 39MHz 8085 32MHz 1900P 65MHz AWS13 70MHz 2300WCS 10MHz 2500_100TDD 194MHz 3500CBRS N A The nominal uplink bandwidth 600 35MHz 700LTE_FN 700FN B1 17MHz 700FN B2 21MHz 8085 32MHz 1900P 65MHz AWS13 70MHz 2300WCS 10MHz 2500_100TDD 194MHz 3500CBRS N A The nominal passband gain Downlink 600 61dB 700LTE_FN 63dB 8085 58dB 1900P 67dB AWS13 67dB 2300WCS 69dB ...

Page 12: ...2 6 kg Internal Common Part 3 0 kg External Power consumption 35W Temperature range 5 C to 50 C Ambient Temperature Humidity Range 5 90 Non condensing Sealing Remote Unit IEC UL CSA 62368 1 Size mm 220 x 220 x 90 Integrated Antenna 200 x 200 x 73 External Antenna 2 1 1 Port on eROU eROUa 2 1 1 1 Functions Integrated Antenna External Antenna Figure 4 The name of each port on eROU ...

Page 13: ...Confidential Proprietary 13 20 External Antenna Figure 5 The name of each port on eROUa ...

Page 14: ...35A 64 8W This product is intended to be supplied by a Listed Switching Adapter marked Class 2 or LPS or PS2 and rated from 100 240V 50 60HZ 1 5A max No Port Quantity Remark 1 Optical Port 1EA LC APC 2 ANTENNA PORT External Only 1EA 2 2 5 type female 3 Power IN 1EA Terminal_Block_CONN_2P TLPS 302V 02P G 4 ADD ON eROU Port 2EA QMA type female 5 ADD ON eROU Port 1EA RJ45 6 USB Port 1EA USB C Type ...

Page 15: ... tools for installing eROU No Tools Q ty Specification Remark 1 1 Ø3 0 Length is more than 20mm For fixing 3 1 1 eROU Enclosure installation The eROU can be mounted on a wall or ceiling and divided into the version of External Antena and the version of Internal Antena Figure 3 eROU appearance Left External Antenna Right Internal Antenna ...

Page 16: ...Confidential Proprietary 16 20 Figure 4 Dimension used to install eROU internal Figure 3 Dimension used to install eROU external ...

Page 17: ...Confidential Proprietary 17 20 Figure 4 Dimension used to install eROUa external ...

Page 18: ...Confidential Proprietary 18 20 3 1 2 eROU eROUa External Antenna Mount Installation ...

Page 19: ...Confidential Proprietary 19 20 3 1 3 Installation Cable Gland 3 1 3 1 eROU 3 1 3 2 Combine of eROU and cROU extended type From To eHUB ...

Page 20: ...r external adapter 2 Cable length between eHub and eROU supports up to 1 km Cable specifications recommend AWG14 and Cable type shall be marked CL2 3 If the maximum length between the eHub and the eROU is exceeded the use of the External Adapter is recommended Adaptor is extra purchases Specified below shall be used only adapter ...