Connecting the induction cooktop to the electrical instalation:
The induction cooktop
can only be connected by qualified installer, with proper authorization. Before
connecting to the current, one should check:
•
Electrical diagram of connecting the induction cooktop to the electrical supply
•
Value of electrical voltage (is located on the rating plate)
•
The compatibility of selected cables with the type of power supply of installation
When connecting of induction cooktop,
it is prohibited to use
extension cords, connectors etc., because
they may cause fire. Conecting cable cannot come into contact with hot or sharp elements of induction
cooktop. All of the changes in the electrical instalation may be made only by an authorized electrician.
Connection diagram for connecting the induction cooktop for electrical installation:
•
In the event of a damaged
power cord
of induction cooktop, it should be replaced in the
repair shop provided for this purpose.
•
If induction cooktop is directly connected to the electrical power supply, the switch is
absolutely essential for all circuits with a air break (contact gap) min. 3mm.
•
A licensed electrician must
check the correct connection
–
the compliance with the
electrical diagram and applicable standards
•
One should pay attention, in order to the power cord was not twisted or pressed by
equipment
•
The connecting cable must be checked regularly by an authorized person. In the event you
need to
replace the cable,
this must also be done by a specialist.
7.
OPERATING INSTRUCTIONS
7.1
Before starting a connected induction cooktop
•
Carefully clean the surface of induction cooktop.