background image

 

 

 

.

 

OPERATION INSTRUCTIONS

 

1. ON/OFF 

-

 Press the POWER   button to turn the A/C on or off. When the unit is turned off, the Timer 

function will be cancelled. The set temperature will be saved.

 

 

2. MODE SELECTION 

-

 Press the MODE button repeatedly to cycle between the different modes: 

Cool, Dry (Dehumidifier) and Fan.

 

 

3. TEMPERATURE SETTING 

-

 Press the 

▼ 

button to decrease the temperature when the unit is on. Stop 

pressing the button when the desired temperature is displayed. Temperature range is 62⁰F

-

86⁰F. Press the 

 

button to increase the temperature when the unit is on. Stop pressing the button when the desired temperature 

is displayed. Temperature range is  62⁰F

-

86⁰F. While the unit is on, press the 

 

and 

▼ 

buttons simultane-

ously to switch between Celsius and Fahrenheit.

 

 

4. FAN 

-

 Press the MODE button to turn on the fan mode.

 

 

FAN HIGH –Press this button to set the fan speed to high. Can be used in COOL or FAN mode. 

FAN LOW –Press this button to set the fan speed to medium. Can be used in COOL or FAN mode. 

QUIET—Press this button to set the fan speed to quiet. Can be used in COOL or FAN mode.

 

 

5. SLEEP MODE 

-

 Press the SLEEP button on the remote control, When in SLEEP mode, the fan will run 

on quiet to keep fan noise at a minimum. The temperature setting will gradually increase to 1°F above 

the original set temperature for each of first 2 hours. The unit will keep operating the same temperature 

until the sleep mode is turned off. Once the SLEEP mode is set, the display of the control panel will 

automatically dim after 10 seconds.

 

 

6. ENERGY SAVER MODE

-

 Press the ENERGY SAVER mode button to turn on ENERGY SAVER 

mode. When the unit is in ENERGY SAVER mode, the ENERGY SAVER light will turn on. Set the 

unit to the desired temperature for the room. Selecting ENERGY SAVER mode will cycle the fan off 

and on with the compressor to limit energy consumption and maintain the desired temperature. Use 

this feature when the room is unoccupied and a greater range of room temperature is acceptable.

 

 

7. AUTO MODE

-

 

Press the AUTO button to activate auto mode. When the unit is in AUTO mode, the unit 

will automatically choose the fan speed and cycle between COOL and FAN modes to maintain the room 

temperature. Auto Mode will operate the unit in COOL mode when the temperature is above 72 degrees, 

FAN mode when the temperature is below 72 degrees.

 

 

8. TIMER 

-

 Press the TIMER button when the unit is off to set up the Auto

-

on timer. The hour indicator 

on the digital display will start flashing. Press the 

▲ 

and 

▼ 

button to set timer within 1

-

24 hours.

 

 

Press the TIMER button when the unit is on to set up the Auto

-

off timer. The hour indicator on the dig-

ital display will start flashing. Press the 

▲ 

and 

▼  

button to set timer within 1

-

24 hours. To cancel the 

timer, press the TIMER button again.

 

 

9. MY TEMP MODE 

-

 

Press the MYTEMP MODE button to change the thermostat sensor from the air 

conditioner to the remote location. When MYTEMP MODE is activated, double hyphen sign "

--

" will 

flash 3 seconds on digital display. The air conditioner will cool the area depending on the location and 

set temperature of the remote control. Take the remote control with you so the air conditioner cools 

the room to your location.

 

 

10

CHILD LOCK

 

Press this button 3 seconds 

to lock/unlock the remote control buttons.            

 

Summary of Contents for WS3-06E-201

Page 1: ...ditioner must be upright for 24 hours prior to operating This ensures that the compressor will function as intended Model WS3 06E 201 6 000 BTU WS3 08E 201 8 000 BTU Electronic Saddle Air Conditioner...

Page 2: ...itioner please read this owner s manual carefully Store this manual in a safe place for future reference Your safety and the safety of others is very important to us Please pay attention to all safety...

Page 3: ...metal The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly To test 1 Plug power cord into wall outlet the LED light will turn on 2 Press TEST Button circu...

Page 4: ...lider Support Bracket 2 Adjustable Support Knob Long 2 Adjustable Support Knob Short 2 Top Foam Sealer 1 Optional Window Security Bracket Security Bracket 1 Type B Screw 1 Owner s Manual 1 Remote Cont...

Page 5: ...Ph V Hz 1 115 60 1 115 60 Rated Cooling Capacity BTU h 6 000 8 000 Cooling Power Input Watts 495 667 Rated Current Cooling Amperage 4 5 6 5 CEER 12 1 12 0 Noise Level dB A 38 49 Indoor 51 63 Outdoor 3...

Page 6: ...plug and current detection device DISCLAIMER ALL INFORMATION AND THE TECHNICAL SPECIFICATIONS PRESENTED IN THIS USER S MANUAL ARE THE PRESENATION OF THE MANUFACTURER SOLEUS N A HAS NOT CONDUCTED AN I...

Page 7: ...w frame This will allow the air conditioner to tilt enough for proper drainage See FIG 2 Prior to Installing the Air Conditioner 1 Check for anything that could block airflow Check the area outside of...

Page 8: ...itioner over the window sill so that the unit straddles the wall 5 Paying close attention to your fingers completely lower the Saddle Air Conditioner onto the window sill 6 Center Saddle Air Condition...

Page 9: ...window sash 5 Close the window sash and seal 6 Plug in Saddle Air Conditioner and Power ON Fig 5 Fig 6 Fig 7 END OF SEASON Remove the Air Conditioner from the Window End of Season 1 Turn the air cond...

Page 10: ...ecrease the timer Auto On Timer When the air conditioner is off it can be set to automatically turn on in 1 24 hours at the previous set mode and fan settings To set the Auto on Timer press the TIMER...

Page 11: ...ot mix old and new batteries or different types of AAA batteries POWER BUTTON UP ARROW TEMP TIMER DOWN ARROW TEMP TIMER SLEEP BUTTON TIMER BUTTON AUTO MODE BUTTON FAN SPEED CHILD LOCK BUTTON MODE BUTT...

Page 12: ...SAVER MODE Press the ENERGY SAVER mode button to turn on ENERGY SAVER mode When the unit is in ENERGY SAVER mode the ENERGY SAVER light will turn on Set the unit to the desired temperature for the roo...

Page 13: ...o High with the temperature set to 65 de grees For Quieter Nighttime Cooling set the mode to Cool and the Fan to Quiet with the temperature set to 72 degrees Energy Saver Mode When the Energy Saver mo...

Page 14: ...ing To clean the air conditioner cabinet Unplug the air conditioner to prevent shock or a fire hazard The cabinet and front panel of the air con ditioner may be dusted with an oil free cloth or washed...

Page 15: ...not stay engaged discontinue use of the air conditioner and contact a qualified service technician The Air Conditioner does not cool as it should Airflow is restricted Make sure there are no curtains...

Page 16: ...y tilted downward from the front of the unit to the rear Firmly press on the drain plug at the front bottom left side of the unit Water collects in the base pan Moisture removed from the air is draini...

Page 17: ...ial handling provisions in the in structions Damage to the finish of the case or other appearance parts caused by wear Damage caused by repairs or alterations of the unit by anyone other than those au...