background image

 

 

 

.

 

OPERATION INSTRUCTIONS

 

1. ON/OFF 

-

 Press the  

  button to turn the A/C on or off. When the unit is turned off, the Timer func-

tion will be cancelled. The set temperature will be saved.

 

 

2. MODE SELECTION 

-

 Press the MODE button repeatedly to cycle between the different modes: Au-

to, Cool/Energy Saver, Dry (Dehumidifier), and Fan.

 

 

3. TEMPERATURE SETTING 

-

 Press the 

▼ 

button to decrease the temperature when the unit is on. 

Stop pressing the button when the desired temperature is displayed. Temperature range is 61⁰F

-

90⁰F. 

Press the 

 button to increase the temperature when the unit is on. Stop pressing the button when the 

desired temperature is displayed. Temperature range is  61⁰F

-

90⁰F.

 

 

4. FAN 

-

 Press the FAN button to turn on the fan mode.

 

 

FAN HIGH –Press this button to set the fan speed to high. Can be used in COOL or FAN mode. 

FAN MED –Press this button to set the fan speed to medium. Can be used in COOL or FAN mode. 

FAN LOW –Press this button to set the fan speed to low. Can be used in COOL or FAN mode.

 

 

5. SLEEP MODE 

-

 Sleep mode can be activated under Cool mode, Dry mode, Auto mode, and Fan mode. 

Press the SLEEP button on the remote control, When in SLEEP mode, the fan will run on low to keep 

fan noise at a minimum. The temperature setting will gradually increase to 2°F above the original set 

temperature for each of first 2 hours. The unit will keep operating the same temperature until the sleep 

mode is turned off.

 

 

6. ENERGY SAVER (On by default) 

-

 Press the ENERGY SAVER button to turn off and on the Energy 

Saver mode. When the unit is in Energy Saver mode, the energy saver light will turn on. Selecting En-

ergy Saver mode will cycle the fan off and on with the compressor to limit energy consumption. Only 

available in COOL mode. Use this feature when the room is unoccupied and a greater range of room 

temperature is acceptable.

 

 

7. TIMER 

-

 Press the TIMER button when the unit is off to set up the Auto

-

on timer. The hour indicator 

on the digital display will start flashing. Press the Timer button to set timer within 1

-

24 hours.

 

Press the TIMER button when the unit is on to set up the Auto

-

off timer. The hour indicator on the dig-

ital display will start flashing. Press TIMER button to set timer within 1

-

24 hours. To cancel the timer, 

press the TIMER button repeatedly until the timer mode is off.

 

 

8. °C

/

°F 

-

 

Press the °C /°F button to switch the temperature between Celsius and Fahrenheit.

 

 

9. MYTEMP MODE 

-

 Press the MYTEMP MODE button to change the thermostat sensor from the air 

conditioner to the remote location. When MYTEMP MODE is activated, double hyphen sign "

--

" will 

flash 3 seconds on digital display. The air conditioner will cool the area depending on the location and 

set temperature of the remote control. Take the remote control with you so the air conditioner cools the 

room to your location.

 

 

10. CHILD LOCK 

-

 Press this button to lock/unlock the remote control  buttons.

 

 

Summary of Contents for WS2-15E-201

Page 1: ...rs prior to operating This ensures that the compressor will function as intended Model WS2 15E 201 15 000 BTU WS2 18E 201 18 300 BTU WS2 24E 201 24 000 BTU Electronic Window Air Conditioner Operating...

Page 2: ...itioner please read this owner s manual carefully Store this manual in a safe place for future reference Your safety and the safety of others is very important to us Please pay attention to all safety...

Page 3: ...sed metal The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly To test 1 Plug power cord into wall outlet the LED light will turn on 2 Press TEST Button ci...

Page 4: ...al 1 Weather Insulation Board 2 Window Sash Seal 1 Window Support Bracket 2 TOOLS NEEDED Large Flathead Screwdriver Tape Measurer Adjustable Wrench or Pliers Pencil Level Socket Wrenches Phillips Head...

Page 5: ...t Dimensions W x H x D 23 625 x 17 75 x 25 375 Package Dimensions W x H x D 26 125 x 20 x 30 5 Net Gross Weight Lbs 110 121 Refrigerant Type R 410A Plug Type NEMA 5 15P Model WS2 18E 201 WS2 24E 201 P...

Page 6: ...INFORMATION AND THE TECHNICAL SPECIFICATIONS PRESENTED IN THIS USER S MANUAL ARE THE PRESENATION OF THE MANUFACTURER SOLEUS N A HAS NOT CONDUCTED AN INDEPENDENT TEST TO VERIFY THE INFORMATION AND SPE...

Page 7: ...ill allow the air conditioner to tilt enough for proper drainage See FIG 2 Prior to Installing the Air Conditioner 1 Check for anything that could block airflow Check the area outside of the window fo...

Page 8: ...crews and remove These screws will need to be re installed prior to mounting the air condi tioner See Fig 4 4 After removing the screws gently pull away the faceplate from the air conditioner cabinet...

Page 9: ...ain Fig 11 Fig 8 Curtain Fig 9 Fig 10 Fig 11 Weather Insulation Boards Fig 12 Long Screw Place the Cabinet Inside the Window 1 Set the cabinet in the window so that is centered Place the unit so that...

Page 10: ...at the marked position as shown above Hand tighten but not all the way for any changes that may need to be made later during installation 3 Install the support brackets with sill angle brackets attach...

Page 11: ...l and the air filter Use the REMOVE CHASSIS instructions and figures 3 7 on page 8 for reference Extend the Curtain Panels 1 Carefully raise the window to expose the curtain panel and panel frame Exte...

Page 12: ...Energy Saver Timer Set 7 Use these buttons on the control panel and remote control to set the timer Each press of the or button will increase or de crease the timer Auto On Timer When the air conditio...

Page 13: ...REMOTE CONTROL Battery Size AAA NOTE Do not mix old and new batteries or different types of AAA batteries LCD Display MODE SLEEP FAN HIGH ENERGY SAVER FAN MED TIMER FAN LOW C F CHILD LOCK MYTEMP MODE...

Page 14: ...ill keep operating the same temperature until the sleep mode is turned off 6 ENERGY SAVER On by default Press the ENERGY SAVER button to turn off and on the Energy Saver mode When the unit is in Energ...

Page 15: ...ture set to 72 degrees Energy Saver Mode When the Energy Saver mode is ON the fan will cycle on and off with the compressor This results in more variations of room temperature and humidity Normally it...

Page 16: ...his will protect the compressor and extend product life Cabinet Cleaning To clean the air conditioner cabinet Unplug the air conditioner to prevent shock or a fire hazard The cabinet and front panel o...

Page 17: ...not stay engaged discontinue use of the air conditioner and contact a qualified service technician The Air Conditioner does not cool as it should Airflow is restricted Make sure there are no curtains...

Page 18: ...ir conditioner is slightly tilted downward from the front of the unit to the rear Water collects in the base pan Moisture removed from the air is draining into the base pan This is normal for a short...

Page 19: ...al handling provisions in the in structions Damage to the finish of the case or other appearance parts caused by wear Damage caused by repairs or alterations of the unit by anyone other than those aut...